Transmitting Measurement Results

scanCONTROL 30xx offers the following options for transmitting measurement results:

 - Ethernet interface

 

ƒ

Modbus TCP protocol

 

ƒ

UDP protocol

 

ƒ

Analog output of measurement values (via optional

 

2D/3D Output Unit)

 

ƒ

Digital output of switching signals (via optional 2D/3D Output Unit)

 

ƒ

Fieldbus connection PROFINET, EtherNet/IP, EtherCAT (via optional 2D/3D Gate-
way)

 - RS422 interface

 

ƒ

Modbus RTU protocol

 

ƒ

Measurement value transmission in ASCII format

7. 

System Requirements 

scanCONTROL Configuration Tools

The following minimum system requirements are necessary: 

 - Windows 7, Windows 8 or 8.1, Windows 10 (each 32 bit and 64 bit) 
 - 1-GHz or faster (32 bit and 64 bit) processor / 1 GB RAM (recommended 4 - 8 GB)
 - Screen resolution: 1024 x 768 (recommended 1920 x 1080)

scanCONTROL 3D-View

The following minimum system requirements are necessary: 

 - Windows 8 or 8.1, Windows 10 (each 64 bit) 
 - 1-GHz or faster (64 bit) processor
 - 1 GB RAM (recommended 16 GB)
 - Screen resolution: 1024 x 768  (recommended 1920 x 1080)
 - Graphics card / GPU with OpenGL 3.1 or higher

Содержание scanCONTROL 30 BL Series

Страница 1: ...etergents cooling emulsions Damage to or destruction of the sensor Read the detailed operating instructions before operating the sensor These instructions are available online at www micro epsilon com...

Страница 2: ...he sensor housing LASER RADIATION DO NOT STARE INTO BEAM OR EXPOSE USERS OF TELESCOPE OPTICS CLASS 2M LASER PRODUCT IEC 60825 1 2014 P 10 mW P 10 mW E 6 mW cm 0 P 658nm F 0 25kHz t 7 s LASER RADIATION...

Страница 3: ...ns LED Displays 1 2 1 Multifunction port power supply I O 2 Ethernet port Multifunction Port Designation Sensor connector pin Cable color PCR3000 x Notes Ub 9 Red 11 V 30 V DC rated value 24 V max 5 W...

Страница 4: ...ts of the multifunction port can either be used for encoder input trigger input or for load previously stored user modes The signal levels are switchable for all switching inputs between LLL TTL logic...

Страница 5: ...is setting is activated by default and has priority over search the link local net The sensor scanCONTROL 30xx supports Power over Ethernet If the sensor is connected to a POE capable network adapter...

Страница 6: ...us RTU protocol Measurement value transmission in ASCII format 7 System Requirements scanCONTROL Configuration Tools The following minimum system requirements are necessary Windows 7 Windows 8 or 8 1...

Страница 7: ...Close unused connection plugs with the included protective caps Turn on the power supply 24 VDC Please wait until the scanCONTROL measuring system is recognized by the PC This may take a few seconds N...

Страница 8: ...scanCONTROL and the PC On the left side you can adjust the settings for your measurement task the right side shows the profile data and information about the measurement 10 How to Access Profile Data...

Страница 9: ...us systems Furthermore all scanCONTROL sensor settings can be set via the 2D 3D Gateway e g Laser on off or switch User Mode Sensor parameterization Power supply Triggering Encoder Synchronization Mod...

Страница 10: ...ply OUT 24 V 0 V 0 V System supply In 24 V 0 V OU filter module 2 5 3 0 5 7 LINK ACT MS I O ETHERNET NS 8 7 6 5 4 3 2 1 N O LINK ACT 1 2 X 1 X 2 8 1 ON 24V X3 0V 0 WBM 255 DHCP OU fieldbus coupler L1...

Страница 11: ...e Digital output terminals need a field supply of 5 VDC or 24 VDC depending on the module type After mounting the modules install the required wiring Connect the System supply out contacts of the OU F...

Страница 12: ...ocumentation the Status and Error Messages and Notes sections in the scanCONTROL Configuration Tools operating instructions You will find details about the individual programs in the respective operat...

Отзывы: