Page 49
scanCONTROL Output Unit
scanCONTROL 25xx
7.4
Specification of the Components
7.4.1
Output Unit Basic
Micro-Epsilon order no. 6414073
Consists of
- OU-Fieldbus Coupler/Ethernet
- OU-Filter module
- OU-Bus termination module
- Interfaces: 2x Ethernet to connect
scanCONTROL 2510 sensors.
- Indicators (Status LED’s, for detailed
description refer to the manual of the
OU-Fieldbus Coupler/Ethernet)
- The system supply is already mounted
to the Fieldbus Coupler.
Fig. 24 OU-Fieldbus Coupler/Ethernet with system supply module
System data
Max. number of bus sharing unit
Limited by Ethernet specification
Max. length of fieldbus segment
100 m
Baud rate
10/100 Mbit/s
Technical Data
Number of bus terminals
64
With bus extension
250
Power supply
DC 24 V (-25 % ... +30 %)
Max. input current
280 mA at 24 V
Internal current consumption
450 mA at 5 V
Total current for I/O modules
700 mA at 5 V
Voltage drop at I
max.
< 1 V at 64 I/O modules
Fig. 25 Technical data Fieldbus Coupler/Ethernet