Page 38
Operation
optoCONTROL CLS1000
5.4.5
ANA / Config AO
The
ANA
menu is only available in the optoCONTROL CLS1000-AU and -AI models.
Autom. spread
SPRD
AUTO
Manual spread
SPRD
MAN
Config AO
MENU
ANA
ANA
TYPE
Spread
ANA
SPRD
4
0
0
0
TYPE
4
1
0
0
Values: - 0-20: Current output
0 ... 20 mA
- 4-20: Current output
4 ... 20 mA
Value
Set spread
SPRD
SET
4
2
0
0
4
2
2
0
4
2
3
0
Offset
MAN
OFFS
Factor
MAN
GAIN
Spread point 1
AUTO
SP1
Spread point 2
EXIT
SP2
SET
4
2
1
0
Values:
- OFF: Spread disabled
- ON: Spread enabled
Value
OFFS
4
2
1
0
Values:
0 ... 4095[ms]
Value
GAIN
4
2
2
2
Values:
Value
4
2
3
1
4
2
3
2
+- 0,1 ... 10,0
Output type
1
see separate view in the
chapter Signal Spread
Display Value and Analog
Output
see separate view in the
chapter Signal Spread
Display Value and Analog
Output
Fig. 36 ANA / Config AO menu
The output values depend on the teach-in and value range signal spread
for analog output.