Page 62
Set Sensor Parameter
optoNCDT 1420
7.4.9.2
Zeroing, Mastering with Hardware Input
LED
state
Measuring
Green, red
1
, yellow,
depends on
measuring position.
yellow
yellow
Pin 9
(violet)
Pin 9
(violet)
t 0
2 s
t 1
t 2
2 s
t 3
30 ms ... <3 s
i
A pulse on the function-
al input can be made
via pin 9 pigtail resp.
via the violet wire on
the sensor cable resp.
via the PCF1420-x.
Details of the hardware
input can be found in
the electrical connec-
tions, see Chap.
.
Fig. 35 Flow chart for zeroing, mastering (hardware input)
LED
state
Measuring
Green, red, yellow,
depends on
measuring position
yellow
Pin 9
(violet)
t 0
2 s
t 1
5 s ... <10 s
Fig. 36 Flow chart for the return of zero setting and mastering
The function zeroing/mastering can be applied successive in several times. Between repeating the zeroing/
mastering function a pause of 1 s is required. The zeroing/mastering function can also be combined with the
select
key.
1) With red
State
LED, the master value is not accepted, flashes with 8 Hz for 2 s.
Содержание ILD 1420-10