Page 77
Appendix | ASCII Communication with Sensor
C-Box/2A
A 2.3.6.7 Function Selection Multifunctional Input
MFIFUNC NONE|MASTER|SENSOR1|SENSOR2|SENSOR12 LLL|HLL
Function of the multifunction input, either masters or output to one or both multifunction outputs (sensor).
- NONE: No function
- MASTER: C-Box Mastering
- SENSOR1: Multifunction output for sensor 1
- SENSOR2: Multifunction output for sensor 2
- SENSOR12: Multifunction output for sensor 1 and 2
- LLL: Low Level Logic input
- HLL: High Level Logic input
Default = NONE LLL
A 2.3.6.8 Activate Error Output, Switching Output 1
ERROROUT1 SENSOR1ERROROUT1|SENSOR1ERROROUT2|SENSOR2ERROROUT1|SENSOR2ERROROUT2|S
ENSOR1VALUE|SENSOR1INTENSITY|SENSOR1SHUTTER|SENSOR1REFLECTIVITY|SENSOR2VALUE|SE
NSOR2INTENSITY|SENSOR2SHUTTER|SENSOR2REFLECTIVITY|C-BOXVALUE|LOW|HIGH
Select the signal source for the switching output 1 (to the periphery).
The first four switches only one error output of the sensors.
The next nine monitoring values from the sensors or the C-Box.
The last two switch the output to a level by command.
Default = LOW