Page 73
Appendix | ASCII Communication with Sensor
C-Box/2A
1) Only those values are possible, which are supported by the sensor.
A 2.3.5.3 Measured Value Averaging Controller
AVERAGE NONE|MOVING|RECURSIVE|MEDIAN [<Averaging depth>]
Output averaging of the C-Box/2A. The averaging value affects on the C-Box/2A measured value on all inter-
faces and analog.
- NONE: Measured value averaging not active
- MOVING: Moving average value (averaging depth 2, 4, 8, 16, 32, 64, 128, 256 and 512 possible).
- RECURSIVE: Recursive average value (averaging depth 2, 4, 8, ..., 32768)
- MEDIAN: Median (averaging depth 3, 5, 7 and 9 possible)
Default: NONE
A 2.3.5.4 Measured Value Averaging Sensor
AVERAGE1 NONE|MOVING|RECURSIVE|MEDIAN [<Averaging depth>]
Averaging in the sensors. The averaging value always affects all to be output displacement and difference
values.
- NONE: Measured value averaging not active
- MOVING: Moving average value
1
- RECURSIVE: Recursive average value
1
- MEDIAN: Median
1
The command
AVERAGE2 NONE|MOVING|RECURSIVE|MEDIAN [<Averaging depth>]
stops
averaging the sensor connected to the socket Sensor 2.
Default = NONE
A 2.3.5.5 Setting Masters / Zero
MASTERMV NONE|MASTER <Master value>
Mastering the C-BOXVALUE
- NONE: Terminates the mastering
- MASTER: Setting the current measured value as master value
Master value in millimeters (min: -1024.0 mm, max: 1024.0 mm)
In case of master value is 0, then the mastering function has the same functionality as the zero setting.
Default = NONE
Содержание C-Box/2A