Appendix | ASCII Communication with Sensor
C-Box/2A
A 2.3.4.2 Load Parameter
READ ALL|DEVICE|MEAS 1|2|3|4|5|6|7|8
Read the current parameter under the specified number in the flash. In addition, the size of the loaded data
needs to be specified:
- ALL: All parameters are loaded.
- DEVICE: Only the standard device settings are loaded (interface parameter).
- MEAS: Only the measurement settings are loaded (all features for the measurement).
A 2.3.4.3 Default Settings
SETDEFAULT [ALL] [NODEVICE]
- Sets the default values (Reset to default setting).
- ALL: All setups are deleted and default parameters are loaded, otherwise, only the current setup will be
deleted.
- NODEVICE: Settings of IP address are kept temporarily.
A 2.3.5
Measurement
A 2.3.5.1 Measurement Mode
MEASMODE SENSOR1VALUE|SENSOR12THICK|SENSOR12STEP
Set measurement mode, possible are:
- SENSOR1VALUE: Measured value of sensor 1.
- SENSOR12THICK: The measured values of sensor 1 and sensor 2 are subtracted from measuring range
and both results are added together. If the mastering is active, both values are subtracted from the internal
mastering offset.
- SENSOR12STEP: Difference from measured value of sensor 1 minus measured value of sensor 2.
Default = SENSOR1VALUE
A 2.3.5.2 Measuring Rate
MEASRATE x.xxx
Measuring rate in kHz with three decimal places.
Only measuring rates that support the measuring rates are permit. During deactivated synchronization values
between 0.400 and 80.000 are permitted.