ALARM REGISTERS
3.4.
0Bh
– Seconds Alarm
This register holds the Seconds Alarm Enable bit AE_S and the alarm value for seconds, in two binary coded
decimal (BCD) digits. Values will range from 00 to 59.
Address
Function
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
0Bh
Seconds Alarm
AE_S
40
20
10
8
4
2
1
Reset
1
0
0
0
0
0
0
0
Bit
Symbol
Value
Description
7
AE_S
Seconds Alarm Enable bit (see ALARM FUNCTION)
0
Enabled
1
Disabled
– Default value
6:0
Seconds Alarm
00 to 59
Holds the alarm value for seconds, coded in BCD format.
0Ch
– Minutes Alarm
This register holds the Minutes Alarm Enable bit AE_M and the alarm value for minutes, in two binary coded
decimal (BCD) digits. Values will range from 00 to 59.
Address
Function
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
0Ch
Minutes Alarm
AE_M
40
20
10
8
4
2
1
Reset
1
0
0
0
0
0
0
0
Bit
Symbol
Value
Description
7
AE_M
Minutes Alarm Enable bit (see ALARM FUNCTION)
0
Enabled
1
Disabled
– Default value
6:0
Minutes Alarm
00 to 59
Holds the alarm value for minutes, coded in BCD format.