background image

©2021 Micro-Air corp.  

rev. 1.06 

 

Safety and Warnings 

 

AC Power can be dangerous or lethal if the proper safeguards are not understood or performed.  

 

If you are not sure of any aspect of this installation or proper safety when working with AC line 
voltages, please seek installation by a qualified HVAC or electrical professional. 

 

Turn off all power to the air conditioning system before proceeding.  

 

Read all instructions before starting installation. 

 

Capacitors can store a charge and should be discharged by touching both terminals 
simultan

eously with an insulated screw driver. Three terminal caps should use the “C” terminal 

to short each of the other two terminals.  

 

 

Содержание EasyStart Home

Страница 1: ...terminal run capacitors 4 Two terminal run capacitors 4 Step 4 Removing start devices 5 Step 5 Check for compressor monitoring systems 5 Step 6 Connecting the ORANGE wire 5 Step 7 Connecting the BROWN wire 6 Step 8 Connecting the WHITE wire 6 Step 9 Connecting the BLACK wire 7 Step 10 Learning 7 Appendix 1 Compressor monitoring system changes 8 Models without Bluetooth 8 Models with Bluetooth 8 Ap...

Страница 2: ...g with AC line voltages please seek installation by a qualified HVAC or electrical professional Turn off all power to the air conditioning system before proceeding Read all instructions before starting installation Capacitors can store a charge and should be discharged by touching both terminals simultaneously with an insulated screw driver Three terminal caps should use the C terminal to short ea...

Страница 3: ...dditional components and may have a circuit board as well Power comes in from the bottom of the contactor usually from a breaker or fuse panel on the dwelling This must be disconnected Turn the breaker off before connecting EasyStart Step 2 Mounting the unit EasyStart can be mounted on any flat surface in either a horizontal or vertical position It can also be mounted with the clear cover pointing...

Страница 4: ...re to make connections Two terminal run capacitors Wire to contactor and capacitor Two terminal group caps are harder to identify the terminals because they are not labeled Look for a wire that connects the contactor to the capacitor like the red one shown in figure 3 This wire is connected to the C terminal and will be left in place The other unmarked terminal is the HERM terminal For the remaind...

Страница 5: ...h is a small disk Remove this start assist wire from the herm terminal at both ends while leaving all the other HERM wires alone If you have a PTC or hard start you can just remove the entire device Step 5 Check for compressor monitoring systems Some systems have monitoring circuit that verifies the compressor is running and provides feedback like a lights or fault indication when the compressor f...

Страница 6: ...nect the disconnected wire to the BROWN wire from EasyStart Connect only these two wires together and not to anything else Step 8 Connecting the WHITE wire Connect the EasyStart WHITE wire to the contactor where the wire was removed from in the last step This is typically under the screw terminal on the contactor Note Compressors with an RLA over 18 amps should not use the spade connection like sh...

Страница 7: ...rent in your installation Connect the BLACK EasyStart wire to the side of the contactor where the EasyStart WHITE wire is NOT connected using an available connection point Connect here Step 10 Learning Start the air conditioner on AC mains power The fan will come on followed shortly after by the compressor EasyStart is now installed The compressor can be cycled normally to complete the learning pr...

Страница 8: ...tion Turn off the breaker to the air conditioner Connect the black and white EasyStart wires to the line input side of the contactor indicated by the yellow arrows in figure 8 Tape or wire nut the EasyStart brown and orange wire ends so they cannot make electrical contact with anything Turn on the breaker to the air conditioner Open the smart device application on an Android or Apple device To sta...

Страница 9: ...rmal rain events The box should not be pressure washed since it is not rated for high power water jet cleaning It can be washed with a mild soap and water solution Appendix 3 Additional Resources For additional information on EasyStart troubleshooting or assistance please visit our website at www Microair net ...