Squeegee System 190
Service Manual – SC8000
Vacuum Fan On and Squeegee Down
The following conditions must be met for the Vacuum Fan to run and for the squeegee to be lowered to the
pick-up position:
• The
Key Switch
must be on.
• The engine must be running.
• The scrub on mode must be selected or the vacuum system switched on at the
Dashboard Panel
.
• The drive pedal must be activated (moved from the neutral position).
Component
Current - Amps
Coil Resistance - Ohms
L1
1.5 Amps
8 ohms
L2
1.5 Amps
8 ohms
PIN J2-5
L2
SQUEEGEE
DOWN
B-
B+ from
K1 Power Relay
B- OUTPUT
TOUCH PAD
DASHBOARD PANEL
BRN/YEL
VACUUM FAN ON & SQUEEGEE DOWN
PIN J2-8
B- OUTPUT
L1
VACUUM FAN
SOLENOID
RED/GRA
B+
CB5
10A
GRN/BRN
B-
DRIVER BOX
S1
KEY SWITCH
B1
12VDC
12VDC