GPH-SERIES Operator's Manual
Engine will not start.
Various engine problems.
Refer to the Engine Manual
accompanying your unit.
Unit components are frozen.
Allow to thaw. If any part of the unit
becomes frozen; excessive
pressure may build up in the unit
which could cause the unit to burst
resulting in possible serious injury to
the operator or bystanders.
No discharge at nozzle when
Inadequate water supply.
Ensure hose is 3/4" diameter and
trigger mechanism is squeezed.
incoming water supply is turned on.
Low or fluctuating pressure.
Kink in water inlet hose.
Remove kink.
Kink in high pressure discharge hose. Replace kinked high pressure hose.
Water inlet screen obstructed.
Remove screen, clean or replace.
Pump sucking air. (Prime eliminated) Tighten all water intake connections
Eliminate leaks in intake line.
Collar on adjustable nozzle is not in
Turn Collar
clockwise
to move
the high pressure mode.
to high pressure.
Obstructed or worn spray nozzle.
Remove, clean or replace.
Damaged or obstructed valve assy.
Remove, inspect, clean or replace.
on pump.
Pump packings worn.
Replace packings.
Unloader/Bypass valve not operating
Repair or replace.
correctly.
Water is leaking from the "Heat Dump Water temperature is too high.
Do not allow unit to operate in
Valve".
bypass mode (with the trigger gun
closed) for more than 3 minutes.
Defective valve.
Replace
Oil appears milky or foamy.
Water in oil.
Change pump oil. Fill to proper
level.
Oil leaking from unit.
Worn seals or o-rings.
Contact your Customer Service.
Detergent will not siphon into
Detergent strainer is not completely
Check, submerge if necessary.
Low Pressure Detergent mode.
submerged in detergent solution.
Detergent strainer obstructed.
Inspect, clean or replace.
Detergent hose cut, obstructed or
Inspect, clean or replace.
kinked.
Detergent adjusting knob turned to
Open adjusting knob. Refer to
closed position.
"Cleaning with Detergents" pg. 5.
Collar on adjustable nozzle is
Turn collar
counterclockwise
to
not in low pressure mode.
move to low pressure.
Nozzle assembly is plugged.
Clean or replace.
Too many high pressure hose
Use one extension maximum.
extensions attached to the water outlet.
Ball & Spring in Venturi stuck.
Remove, clean or replace.
Water flows back into detergent
Ball & Spring in Venturi reversed,
Remove, clean or replace.
container.
missing or corroded.
Water flows from the nozzle when the Trigger gun is malfunctioning.
Repair or replace.
trigger gun is locked in the "OFF"
position.
fOR CUsTOmER sERvICE CAll: 1-800-648-8478
troublesHooting
SYMPTOM
PROBABLE CAUSE
REMEDY