operating instructions
Hot water operation:
. Follow the steps outlined for "START-UP/COLD WATER OPERATION".
2. Move the Burner Switch to the ON position. On initial start-up, water will
begin turning hot in approximately 20 seconds and will reach maximum
temperature in approximately 2-/2 minutes, provided the trigger remains
squeezed. The burner will stop firing when the trigger is released.
NOTE:
While spraying, it is normal for the burner to fire intermittently. The
high-limit switch will cause combustion to cease when the temperature
of the discharged water exceeds the maximum temperature setting of
the switch. Combustion will begin again when the temperature drops
below the minimum setting.
At this point, the unit is operating as a hot water pressure washer. Be certain to
be extremely cautious when adjusting the pressure and controlling the trigger
gun/lance assembly to avoid the possibility of burns.
cleaning witH detergents under low pressure:
NOTE:
This feature is designed for use with mild detergents only. Since the
cleaning solution travels through the heat exchanger coil, DO NOT
use corrosives as they will cause extensive damage as well as pose a
considerable safety hazard.
. Prepare detergent solution according to label directions. Never pump acids,
alkaline, abrasive fluids or solvents through the unit.
2. Adjust the amount of detergent desired by locating the adjustment knob at
the end of the clear vinyl hose. Turn the knob completely counterclockwise
to set at maximum siphon rate.
3. Fully immerse the deteregent strainer into the detergent solution.
4. With the trigger gun locked in the "OFF" position, rotate the adjustable
nozzle
counterclockwise
.
NOTE:
This injection system is designed to apply detergents under low pressure
only. It will not allow detergent solutions to be introduced into the system
unless the adjustable nozzle is set in the low pressure mode.
5. To apply solution; unlock the trigger gun and squeeze the trigger. In a few
moments a detergent/water mixture will exit the nozzle. Start spraying
the lower portion of the surface being cleaned and move up, using long
overlapping strokes. Applying from the bottom up helps avoid streaking.
Allow to soak briefly. (Avoid working on hot surfaces or in direct sunlight to
minimize the chances of the detergent drying, which may result in damaging
painted surfaces.) Be certain to rinse a small section at a time.
6. To rinse; lock the trigger gun in the "OFF" position, rotate the adjustable
nozzle
clockwise
for high pressure. Unlock the trigger gun and spray. It
will take about 30 seconds to purge all detergent from the line. For best
rinsing results, start at the top and work down.
7. Siphon a gallon of water through the low pressure detergent injection system
after each use. This prevents the possibility of corrosion or detergent residue
causing mechanical problems during the next use.
sHut-down:
. Move the Burner Switch to the OFF position.
2. Squeeze the trigger and discharge the water for a period of three minutes
to cool the heat exchanger and high pressure hose. (Insufficient cool down
period of the high pressure hose will cause excessive wear and eventual
rupturing of the hose.)
3.
do not close the choke to stop the engine.
Backfire or engine damage
may occur. Turn the engine "OFF" as directed in the engine manual.
4. Close the engine fuel shut-off valve.
5. Turn the water supply "OFF".
6. Pointing the gun in a safe direction, trigger the gun momentarily to relieve
trapped pressure.
7. Disconnect and drain the nozzle assembly, gun, wand and hoses.
8. Store complete assembly in a non-freezing environment.
WARNING
risK of burn!
tHe water temperature
could become Very Hot
during Hot water oper-
ation. be cautious wHen
adJusting pressure or
controlling tHe trigger
gun/lance assembly.
detergent mode
Содержание GPH-2000-0M1R
Страница 23: ...Manual del operador SERIE GPH 23 NOTES ...
Страница 46: ...46 Manual del operador SERIE GPH NOTA ...
Страница 47: ...Manual del operador SERIE GPH 47 NOTA ...
Страница 48: ...48 Manual del operador SERIE GPH ...