GPH-SERIES Operator's Manual
DANGER
risK of inJection causing
seVere inJury!
-Keep clear of noZZle! neVer
place Hand or fingers in
front of noZZle!
-do not direct discHarge
stream at people or pets!
CAUTION
risK of damage.
do not allow spray pattern
to remain on a fiXed area
for an eXtended period of
time. possible damage may
occur to tHe area.
operating instructions
priming tHe pump:
It is essential to prime the pump and flush the unit each time the water supply
has been disconnected from the unit OR whenever the unit has set for any
period of time. This unit has a steel coil which, after setting, will cause the
water remaining in the coil from the previous usage to turn brown or black.
This contaminated water must be flushed from the system before start-up.
This procedure should be performed
without
the high pressure hose, gun and
nozzle assembly installed.
. Turn on the water supply.
2. Low pressure water will begin flowing from the water outlet. This allows the
unit to prime and purge any air from the system. The unit is primed when
water flow is uninterrupted by air.
3. Once the unit is primed, turn off the water supply and connect the high
pressure discharge hose/gun to the water outlet of the unit.
4. Turn on the water supply.
start-up/cold water operation:
. Refer to the "Safety Precautions" pgs. 4-7 before starting the unit.
2. Locate the Safety Decals on your unit and heed their warnings.
3. Ensure the burner switch is in the "OFF" position.
4. Perform the following engine start-up procedures.
a. Point the trigger gun in a safe direction, disengage the safety lock on
the gun and squeeze the trigger.
b. Brace yourself for kickback from the high pressure created by the pump
once the engine has started.
c. Hold the trigger gun open while starting the engine according to the
manufacturer's instructions in the engine manual accompanying this
unit.
5. Once the engine has started, perform the following procedures with the
trigger gun open:
a. Inspect for system water leaks, oil leaks and fuel leaks. If a fuel leak
is found, TURN UNIT OFF IMMEDIATELY! See "Risk of Explosion or
Fire", pg. 4. Be sure that all damaged parts are replaced and that the
mechanical problems are corrected prior to operation of the unit. If you
require service, contact Customer Service.
b. Inspect high pressure hoses for kinking, cuts and leaks. If a cut or
leak is found, DO NOT TOUCH HOSE AT LEAK!!! TURN UNIT OFF
IMMEDIATELY! Replace hose before restarting the unit. See "Risk
of Injection", pg. 5. Be sure that all damaged parts are replaced and
that
the mechanical problems are corrected prior to operation of the
unit. If you require service, contact Customer Service.
6. Trigger the gun several times and try adjusting the water pressure. NEVER
place hand or fingers in front of the nozzle or look directly into the nozzle!
High pressure water creates a risk of severe injury!
7. Do not allow unit to operate in bypass mode (with trigger closed) for more
than three minutes without triggering the gun. Failure to follow this simple
rule can cause premature failure of pump packings, resulting in costly pump
repair.
8. Your pressure washer can deliver high pressure spray and a variety of spray
patterns using cold water. If you wish to use the Hot Water application or
Cleaning with Detergents, see page 5 for the correct procedures.
CAUTION
risK of unit damage.
be certain tHe Hose, gun
& noZZle assembly are
not connected to tHe
unit wHile priming tHe
pump. priming allows
mineral deposits to be
released from tHe system
wHicH would obstruct
or damage tHe gun and
noZZle assembly resulting
in costly repairs.
Содержание GPH-2000-0M1R
Страница 23: ...Manual del operador SERIE GPH 23 NOTES ...
Страница 46: ...46 Manual del operador SERIE GPH NOTA ...
Страница 47: ...Manual del operador SERIE GPH 47 NOTA ...
Страница 48: ...48 Manual del operador SERIE GPH ...