background image

Operator’s Manual  

1

©

Copyright 2020, Mi-T-M 

      

Form #37-1476-E-042220

OPERATION MANUAL

CM-1400-0MEC-M
CM-1400-1MEH-M

COLD WATER ELECTRIC

PRESSURE WASHER AND

MISTER COMBINATION UNIT

CAUTION

RISK OF INJURY!  READ ENTIRE MANUAL BEFORE 

OPERATING!  THIS MANUAL IS AN IMPORTANT PART 

OF THE PRESSURE WASHER AND MUST REMAIN WITH 

THIS UNIT!

Содержание CM-1400-0MEC-DM

Страница 1: ...2220 OPERATION MANUAL CM 1400 0MEC M CM 1400 1MEH M COLD WATER ELECTRIC PRESSURE WASHER AND MISTER COMBINATION UNIT CAUTION RISK OF INJURY READ ENTIRE MANUAL BEFORE OPERATING THIS MANUAL IS AN IMPORTANT PART OF THE PRESSURE WASHER AND MUST REMAIN WITH THIS UNIT ...

Страница 2: ...ovided from your dealer for customers who operate and maintain their equipment as described in this manual The warranty is explained on the warranty certificate shown in this manual This warranty provides you the assurance that your dealer will back products where defects appear within the warranty period Should the equipment be abused or modified to change its performance beyond the original fact...

Страница 3: ...e Washer Pressure Washer Mode 17 Preparing the Washer Mister Mode 21 Operating the Washer Mister Mode 24 Troubleshooting 26 Service 28 Storage 30 All information illustrations and specifications in this manual are based on the latest information available at the time of publication The right is reserved to make changes at any time without notice ...

Страница 4: ... near specific hazards General precautions are listed on CAUTION safety signs CAUTION also calls attention to safety messages in this manual FOLLOW SAFETY INSTRUCTIONS Carefully read all safety messages in this manual and on your machine safety signs Keep safety signs in good condition Replace missing or damaged safety signs Be sure new equipment components and repair parts include the current saf...

Страница 5: ... and ordinances DANGER Improper connection of the equipment grounding conductor can result in a risk of electrocution Check with a qualified electrician or service person if you are in doubt as to whether the outlet is properly grounded Do not modify the plug provided with the product if it will not fit have a proper outlet installed by a qualified electrician GROUND FAULT CIRCUIT INTERRUPTER PROT...

Страница 6: ...tions dry and off the ground Do not touch plug with wet hands On extension cords Cable Length Wire Gauge Up to 50 feet 14 AWG 50 to 100 feet 12 AWG Use of smaller cords will cause electric motor stalling or circuit breaker stoppage CLEANING DETERGENT PRECAUTIONS Know the detergent being used Be prepared to tell a physician exactly what you are using in the event of an emergency Read all detergent ...

Страница 7: ...ass or fragile objects that may shatter 7 Dirt and debris removed by spray can cause eye injury Wear eye protection 8 Wet surfaces can be slippery Wear shoes and keep both feet on the ground Do not climb on items being cleaned Do not overreach or stand on unstable support Keep good footing and balance at all times 9 When the spray trigger is released water pressure is trapped in the discharge hose...

Страница 8: ...hing cutting or heat damage Inspect high pressure hose for kinking cuts or abrasive wear PREPARE FOR EMERGENCIES Keep a first aid kit and fire extinguisher handy Keep emergency numbers for doctors ambulance service hospital and fire department near your telephone Be prepared if a fire starts SERVICE HIGH PRESSURE WASHER SAFELY Before servicing washer disconnect unit from power source relieve water...

Страница 9: ...scharge stream at people RISK OF EXPLOSION Do not spray flammable fluids RIESGO DE INYECCIÓN O LESIÓN DE CORTE Manténgase alejado de la boquilla No dirija la corriente de descarga hacia las personas RIESGO DE EXPLOSIÓN No rocie liquidos inflamables WARNING 34 1428 082912 If connection is made to a potable water system the system shall be protected against backflow Do not spray electrical apparatus...

Страница 10: ...rdon électrique S il s avère nécessaire de remplaçer la fiche ou le cordon n utiliser que des pièces de rechange identiques Si cet appareil ne comporte pas un disjoncteur de fuite à la terre ne le relier qu à une prise de courant protégée par un disjoncteur de fuite à la terre L utilisation d une rallonge n est pas recommandée Lire le manuel de l opérateur avant d utiliser l appareil RISQUE D ÉLEC...

Страница 11: ...ter Valve C Detergent Hose D High Pressure Outlet E Water Inlet Fitting F Power Cord G Ground Fault Circuit Interrupter H Discharge Hose I Handle J Gun Trigger K Gun L Nozzle Wand M Nozzles N Quick Connect Misting Nozzle O Misting Gun with Nozzle H N K I A G F L J B M D E C O ...

Страница 12: ...ter Valve C Handle D High Pressure Outlet E Water Inlet Fitting F Power Cord G Ground Fault Circuit Interrupter H Detergent Hose I Nozzle Wand J Gun Trigger K Gun L Discharge Hose M Misting Gun with Nozzle N Quick Connect Misting Nozzle O Nozzles L M K C A G H F D E I J B O N ...

Страница 13: ... cord to reduce the risk of electrical shock However the GFCI will not protect against all faults short circuits or overloads CAUTION Ground Fault Circuit Interrupter GFCI MUST be tested before each use of the washer If the results in each one of the following steps are not as described shut washer off immediately DO NOT operate until the washer has been inspected by a qualified electrician or you...

Страница 14: ...pply Required 4 If non pressurized static draw water supply is used check to be certain flow is at least 125 of pump rated flow In static draw situations water flow rate GPM can be increased by elevating the water supply tank or changing to a larger inside diameter water supply hose 5 For static draw applications the water supply hose should be a good grade of garden hose with an I D of 3 8 in 10m...

Страница 15: ...emove shipping plug and install vented plug A on pump 2 Check oil in pump With washer on level surface the oil should be 1 2 full at the center of sight glass B If necessary add SAE30W non detergent oil so level is 1 2 full at center of sight glass CHECK PUMP OIL B A ...

Страница 16: ...nical screen in washer A should protrude out of coupler and into flow from inlet hose 2 Install inlet water hose A and hand tighten Install high pressure discharge hose B with quick connect Turn Misting Valve C clockwise until fully closed A A B A 3 Open water supply Squeeze trigger on gun Allow water to run with motor off until water runs out of pressure hose Start motor and cycle trigger on gun ...

Страница 17: ... until you release it by triggering the gun Before removing the spray nozzle or servicing the unit always shut off the unit and trigger the gun to release trapped pressure CAUTION Various nozzles may be quick connected into the end of the wand to change the spray pattern or use the detergent feature When using Quick Connects Q C be certain the connection is securely locked If not the high pressure...

Страница 18: ...ical reaction when mixed with another detergent NEVER SPRAY FLAMMABLE LIQUIDS such as gasoline fuel oil alcohol naptha etc Be sure to read and follow all detergent labels exactly regarding preparation use safety transportation and disposal Keep in mind that the washer s detergent system further dilutes the detergent with water and that some detergents may not be concentrated enough to properly wor...

Страница 19: ...e 4 To apply solution unlock the trigger gun and squeeze the trigger In a few moments a detergent water mixture will exit the low pressure nozzle Start spraying the lower portion of the surface being cleaned and move up using long overlapping strokes Applying from the bottom up helps avoid streaking Allow to soak briefly Do not allow detergent solution to dry on the surface Avoid working on hot su...

Страница 20: ...rgent inlet strainer in CLEAN water and operate trigger to spray water for a period of three minutes This will flush the system of detergents and help prevent the detergent valve from sticking or corrosion 2 Turn unit off and unplug washer 3 Turn inlet water supply off Squeeze trigger momentarily to relieve pressure Disconnect hoses 4 Allow motor to cool then wipe washer down with a damp cloth ...

Страница 21: ...ower cord to reduce the risk of electrical shock However the GFCI will not protect against all faults short circuits or overloads CAUTION Ground Fault Circuit Interrupter GFCI MUST be tested before each use of the washer If the results in each one of the following steps are not as described shut washer off immediately DO NOT operate until the washer has been inspected by a qualified electrician or...

Страница 22: ...g and flattening of the supply hose 2 Water supply or chemical tank should be clean and located at or above the height of the unit s water inlet 3 In static draw situations water flow rate GPM can be increased by elevating the water supply tank or changing to a larger inside diameter water supply hose IMPORTANT Inlet water temperature must not be more than 90 F 32 C Damage to the pump may result 1...

Страница 23: ... high pressure discharge hose B with quick connect Turn Misting Valve C clockwise until fully closed NOTE Make sure rubber cap is installed on detergent hose barb for mister mode setup Pump will not prime without cap installed A 3 Place end of high pressure discharge hose in water supply or chemical tank Start motor and allow unit to run until all air has been evacuated from the pump and hose Once...

Страница 24: ...f an emergency Keep all detergent s and chemical s out of reach of children Be aware that two detergent s and chemical s can be mixed on the sprayed surface In this regard some detergent s and chemical s may give off harmful fumes or start an unpredictable chemical reaction when mixed with another detergent s and chemical s NEVER SPRAY FLAMMABLE LIQUIDS such as gasoline fuel oil alcohol naptha etc...

Страница 25: ... the trigger In a few moments a detergent chemical mixture will exit the misting gun assembly Consult detergent and chemical manufacturer for application information 2 Siphon a gallon of water through the pump and hose after each use This prevents the possibility of corrosion or detergent and chemical residue causing mechanical problems during the next use SHUTDOWN IMPORTANT Shutdown procedures sh...

Страница 26: ...reen obstructed Remove screen clean or replace Pump sucking air Prime eliminated Tighten all water intake connec tions Eliminate leaks in intake line Not in high pressure mode Insert a high pressure nozzle Obstructed or worn spray nozzle Remove clean or replace Damaged or obstructed valve assem bly on pump Remove inspect clean or replace Mister valve open while in pressure washer mode Turn mister ...

Страница 27: ...k electrical system requirements Check extension cords for proper gauge Internal pump malfunction Contact your customer service Water Continues to Flow from Spray gun valve malfunction Replace gun Nozzle after Gun Trigger is Released Motor Hums Does Not Turn Pump plungers sticking to Use a 4 mm hex wrench to manually packing due to drying turn and free pump See Service Section Motor malfunction Co...

Страница 28: ...ING DETERGENT HOSE STRAINER Check detergent hose strainer for detergent or contaminant buildup Remove strainer from hose and back flush with clean water and a stiff bristle brush NOTE If strainer frequently becomes plugged check detergent to be sure it is thoroughly mixed CLEANING MISTING NOZZLE Remove nozzle from misting gun assembly Inspect nozzle filter for debris and contaminant buildup Remove...

Страница 29: ... necessary with SAE30W non detergent Do not overfill CHANGING WATER PUMP OIL IMPORTANT Change pump break in oil after first 25 hours of operation and at 250 hour intervals thereafter 1 Place unit on level surface 2 Run unit for a few minutes to warm oil 3 Stop washer Use an 22 mm deep well socket to remove drain plug A to drain oil into container Install plug Do not pollute dispose of waste oil pr...

Страница 30: ...ANT Be careful not to kink hose 3 Fill hose with 50 50 mix of antifreeze 4 While adding antifreeze start washer depress spray gun trigger and let run for 15 seconds 5 Release trigger for 15 seconds NOTE Trigger must be released to pull antifreeze into unloader valve 6 Repeat cycle of 15 seconds trigger on 15 seconds trigger off IMPORTANT Dispose of sprayed solution safely according to instructions...

Страница 31: ...isuse operation at other than recommended speeds pressures or temperature Parts damaged or worn because of the use of caustic liquids or by operation in abrasive or corrosive environments or under conditions causing pump cavitation are not warranted Failure to follow recommended operating and maintenance procedures also voids warranty 3 The use of other than genuine manufacturer repair parts will ...

Страница 32: ...32 Operator s Manual ...

Отзывы: