WARNINGS

IF the INFoRMAtIoN IN theSe INStRuctIoNS 
ARe  Not  FoLLoWeD  eXActLy,  A  FIRe 
oR  eXpLoSIoN  MAy  ReSuLt  cAuSING 
pRopeRty DAMAGe, peRSoNAL INjuRy oR 
LoSS oF LIFe.
–  Do  not  store  or  use  gasoline  or  other 

flammable vapors and liquids in the vicinity 
of this or any other appliance.

–  WhAt to Do IF you SMeLL GAS

•   Do not try to light any appliance.
•   Do not touch any electrical switch; do not 

use any phone in your building.

•   Immediately call your gas supplier from 

a  neighbor's  phone.  Follow  the  gas 
supplier's instructions.

•   If you cannot reach your gas supplier, call 

the fire department.

–  Installation and service must be performed 

by  a  qualified  installer,  service  agency  or 
the gas supplier.

WARNING: Improper installation, adjustment, 
alteration, services or maintenance can cause 
injury or property damage. Refer to this manual. 
For  assistance  or  additional  information 
consult a qualified installer, service agency or 
the gas supplier.   
this  appliance  is  only  for  use  with  the  type 
of  gas  indicated  on  the  rating  plate.  this 
appliance is not convertible for use with other 
gases, unless a certified kit is used. 
this appliance may be installed in an aftermarket*, 
permanently  located,  manufactured  home, 
where not prohibited by local codes.

*Aftermarket:  completion  of  sale,  not  for  purpose  of 
resale, from the manufacturer. 

D u e   to   h I G h   t e M p e R At u R e S ,   t h e 
AppLIANce  ShouLD  Be  LocAteD  out  oF 
tRAFFIc AND AWAy FRoM FuRNItuRe AND 
DRApeRIeS.
chILDReN AND ADuLtS ShouLD Be ALeRteD 
to  the  hAZARDS  oF  hIGh  SuRFAce 
teMpeRAtuRe AND ShouLD StAy AWAy to 
AVoID BuRNS oR cLothING IGNItIoN.
youNG chILDReN ShouLD Be SupeRVISeD 
WheN they ARe IN the SAMe RooM AS the 
AppLIANce.
cLothING oR otheR FLAMMABLe MAteRIAL 
ShouLD Not Be pLAceD oN oR NeAR the 
AppLIANce.
Keep  the  RooM  AReA  cLeAR  AND  FRee 
FRoM coMBuStIBLe MAteRIALS, GASoLINe, 
AND  otheR  FLAMMABLe  VApoRS  AND 
LIquIDS.

INStALLeR: Leave this manual with the appliance.
coNSuMeR: Retain this manual for future refer-
ence.

510528
LX cover

51D0528  2/10  Rev. 9

Содержание LEXINGTON LX32DV

Страница 1: ...e or additional information consult a qualified installer service agency or the gas supplier This appliance is only for use with the type of gas indicated on the rating plate This appliance is not con...

Страница 2: ...ace Installation 23 Check Gas Type 23 Install Gas Piping 23 Checking Gas Pressure 25 Electrical Installation 25 Electrical Wiring 25 Remote Wall Switch 26 Glass Removal 27 Log Placement 28 Air Restric...

Страница 3: ...is not properly installed by a qualified service person with glass door properly seated and sealed combustion leakage can occur CARBON MONOXIDE POISONING Early signs of carbon monoxide poisoning are s...

Страница 4: ...f Massa chusetts Flexline installation must not exceed 36 Code Approval Direct Vent type appliances draw all combustion air from outside of the dwelling through the vent pipe These appliances have bee...

Страница 5: ...ace Controls Hi Lo Knob Blower Control On Off RS Switch FP2710 GAS pressures HIGH ELEVATIONS Input ratings are shown in BTU per hour and are certi fied without deration for elevations up to 4 500 feet...

Страница 6: ...mm 4456M 1124 mm 6 2 5 6 O 1 5 8 8 m m 3 1 6 Q E 7 9 2 m m 4456M 1124 mm 1 25 mm Spacers 510528 LX32 dims Min Rough Opening Depth Min Rough Opening Height 6 1102 mm 33 6M 857 mm 24 610 mm 4056O 1029...

Страница 7: ...lectric Drill and Bits Tee Joint Pliers Square Framing Materials Wall Finishing Materials Piping Complying with Local Codes Caulking Material Noncombustible Fireplace Surround Material Noncombustible...

Страница 8: ...e to heat from appli ance Never obstruct the front opening of the fireplace Do not install in the vicinity where gasoline or other flammable liquids may be stored Vent pipe routing See Venting section...

Страница 9: ...39 991 mm LX36 43 1092 mm LX32 30 762 mm LX36 34 864 mm 6 152 mm 12 305 mm Minimum 46 6M 1187 mm 44 6M 1137 mm FP2711 combustible clearances Side Wall Ceiling Combustible Mantel Noncombus tible Facing...

Страница 10: ...to overlap the black painted face of fireplace OF F FP2712 secure fireplaces Figure 6 Securing Fireplace to Floor and Framing Studs Framing Framing Adjustable Bracket Adjustable Bracket Screws Screws...

Страница 11: ...ure 7 WARNING FP1991 remove screws Flue Pipe Cover Flue Pipe Adapter Screws FP1991 Figure 7 Remove 16 Screws from Flue Pipe Adapter and Flue Pipe Cover 4 Remove eight 8 screws securing the flue pipe t...

Страница 12: ...Be aware of electrical wiring locations in walls and ceilings The following actions will void the warranty on your venting system Installation of any damaged venting component Unauthorized modificati...

Страница 13: ...earances to combustibles at the top of the flue and 1 clearance at the sides and bottom until the flue penetrates the outside wall A minimum 1 clearance all around the flue is acceptable at this point...

Страница 14: ...stem in a Chase below If pipe is enclosed in chase it is not exposed It is very important that the venting system maintain its balance between the combustion air intake and the flue gas exhaust Certai...

Страница 15: ...bove the meter regulator assembly 5 m above the meter regulator assy I Clearance to service regulator vent outlet 3 91 cm 3 91 cm J Clearance to nonmechanical air supply inlet 6 15 cm for appliances 1...

Страница 16: ...zontal Dimension From the Outside Face of the Wall to the Back of the Fireplace Vertical Dimension From the Floor of Unit to the Center of the Horizontal Vent Pipe Dimensions in Feet VENTING INSTALLAT...

Страница 17: ...d vent pipes and fittings have special twist lock connections Assemble the desired combination of pipe and elbows to the appliance adaptor with pipe seams oriented towards the wall or floor Twist lock...

Страница 18: ...er to Page 16 Minimum clearance between vent pipes and combus tible materials is 3 on top and 1 from bottom and sides unless otherwise noted When vent termination exits through foundations less than 2...

Страница 19: ...aximum number of 45 elbows permitted per side wall installation is two 2 These elbows can be installed in either the vertical or horizontal run For each 45 elbow installed in the horizontal run the le...

Страница 20: ...maintain a 4 clearance below snorkel Figure 25 VENTING INSTALLATION FP1965 below grade install 24 Minimum Figure 25 Below Grade Installation Screws Minimum 4 Clearance Ground Window Well Gravel Drain...

Страница 21: ...for required clearances air space to combustibles when passing through ceilings walls roofs enclosures attic rafters etc Do not pack air spaces with insulation Also note maximum vertical rise of the v...

Страница 22: ...r to Figures 27 29 Whenever possible use 45 elbows instead of 90 elbows The 45 elbow offers less restriction to the flow of the flue gases and intake air 5 Place the flashing over the pipe section s e...

Страница 23: ...des not provided A CSA design certified equipment shutoff valve with 1 8 NPT tap is an acceptable alternative to test gauge connection Purchase the CSA design certified equipment shutoff valve from yo...

Страница 24: ...hat you install a sediment trap drip leg in supply line as shown in Figure 34 Locate sediment trap drip leg where it is within reach for cleaning Install in piping system between fuel supply and burne...

Страница 25: ...pressure reading be sure and turn captured screw clockwise firmly to reseal Do not over torque Check test points for gas leaks FP1979 Millivolt gas valve FP1979 Figure 35 Gas Pressure Check at Gas Val...

Страница 26: ...provided NOTE Extended lengths of wire may cause the fireplace not to function properly Longer length of wire is permitted if the wire is made out of larger gauge diameter wire Always check with local...

Страница 27: ...e out and lift glass frame up until it clears three tabs on top of fireplace 3 Set glass frame aside Figure 37 Remove Glass Frame Glass Frame Three Tabs Clamps CAUTION FINAL INSTALLATION Each clamp ha...

Страница 28: ...traces of fibers WARNING The positioning of the logs is critical to the safe and clean operation of this heater Excessive sooting and other problems may result if the logs are not properly and firmly...

Страница 29: ...e of firebox Figure 39 LG804 LX rear log Rear Log 1 LG804 Figure 39 LG803 LX left rear log Bottom Left Log 2 LG803 Figure 40 5 Place bottom left log 2 on two pins against left side of firebox Figure 4...

Страница 30: ...g 7 LG809 Figure 42 7 Place right mid log 7 on two right pins on burner assembly Figure 42 LG806 LX Top left log Top Left Log 4 LG806 Figure 43 8 Place top left log 4 on two pins on left mid log Figur...

Страница 31: ...left mid log 6 pin Figure 45 LG810 LX rockwool Rockwool LG810 Figure 46 LG811 LX rockwool Rockwool Air Space Under Rear Log 11 Break up rock wool ember material into dime sized pieces Place evenly ac...

Страница 32: ...Glass Frame Removal Page 27 2 Using a Phillips screw driver loosen the screw that secures the air restrictor Do not back the screw all the way out 3 Slide the baffle on top of the restrictor plate su...

Страница 33: ...glass use a mild soap solution followed by a dampened towel dampened with clean water only followed by a dry towel without using soap Do not use ammonia or ammonia based glass cleaner on the firescre...

Страница 34: ...orce or attempted repair may result in a fire or explosion D Do not use this appliance if any part of it has been under water Immediately call a qualified service technician to inspect the appliance a...

Страница 35: ...to ignite the pilot Keep knob fully depressed for a few seconds Release and check that pilot continues to burn If the pilot does not stay lit repeat steps 1 and 2 Figure 49 Pilot Position Check for g...

Страница 36: ...o ignite Pilot position Depress and turn knob to pilot position to keep burner off while maintaining the pilot light Figure 52 Depress and turn knob clockwise to OFF position Figure 53 to turn off gas...

Страница 37: ...glass no more than two or three times a season Use a mild glass cleaner to clean the door Do not use abrasive cleaners They will damage the glass surface PILOT AND BURNER FLAMES Visually check pilot a...

Страница 38: ...ute materials may be used cleaning and maintenance CAUTION Always use gloves when handling broken glass WARNING Make sure the glass panel edges do not touch any metal parts during thermal expansion FP...

Страница 39: ...ame impingement REMEDY 1 Replace battery 2 Check connections to ignitor Replace ignitor if ignitor connections are good but there is no spark 3 Check for spark arcing from the elec trode to pilot Adju...

Страница 40: ...23 24 25 26 27 28 29 17 18 2 3 1 6 7 4 5 8 9 10 12 13 14 15 16 11 510528 LX parts WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically app...

Страница 41: ...192 51D0192 17 Wire Harness Male 1 44D0501 44D0501 44D0501 44D0501 18 Wire Harness Female 1 44D0500 44D0500 44D0500 44D0500 19 SIT 820 Nova Valve 1 37D0117 37D0118 37D0117 37D0118 20 Knob Extension Hi...

Страница 42: ...rative Arch Available in Black Textured Black Vintage Iron Gold Tone Brushed Pewter and Gold Nantucket Decorative Arch Available in Black Textured Black Vintage Iron Gold Tone Brushed Pewter and Gold...

Страница 43: ...n Rolling O Decorative Arched Facing LX32RVI LX36RVI yes Vintage Iron Nantucket Decorative Arched Facing LX32NVI LX36NVI yes Rectangular Front Nantucket Vintage Iron LX32RNVI LX36RNVI yes Gold Tone Ro...

Страница 44: ...44 51D0528 LX Series Direct Vent Gas Fireplace...

Страница 45: ...51D0528 45 LX Series Direct Vent Gas Fireplace...

Страница 46: ...o comply with the above requirements provided however that during said thirty 30 day period a battery operated carbon monoxide detector with an alarm shall be installed Massachusetts Residents Only Pl...

Страница 47: ...void if the appliance is not operated and maintained according to the operating instructions supplied with the appliance and does not extend to 1 firebox burner assembly damage by accident neglect mi...

Страница 48: ...CSA P 4 1 09 Based on CSA P 4 1 09 Recherchez dans la brochure les caract ristique de rendement nerg tique de foyer au gaz nerguide Selon CSA P 4 1 09 Efficiency Ratings Model EnerGuide Ratings Firep...