DV Power Vent System

Model

 

7THPDVS

DO NOT STORE OR USE GASOLINE OR 

OTHER FLAMMABLE VAPOURS AND 

LIQUIDS IN THE VICINITY OF THIS OR 

ANY OTHER APPLIANCE.

FOR YOUR SAFETY

WHAT TO DO IF YOU SMELL GAS:

  Do not try to light any appliance.  

 

  Do not touch any electric switch; do not use 

any phone in your building. 

  Extinguish all flames.

  Immediately call your gas supplier from 

  your neighbours phone. Follow the gas 

  suppliers instructions. 

  If you cannot reach your gas supplier call 

the fire department. 

WARNING! 

IF THE INFORMATION IN THIS MANUAL IS 

NOT FOLLOWED EXACTLY, A FIRE OR

EXPLOSION MAY RESULT CAUSING 

PROPERTY DAMAGE,PERSONAL INJURY 

OR LOSS OF LIFE.

Homeowner’s Installation and 

Operating Manual

 

FOR YOUR SAFETY

 

   Installation and service must be performed 

by  a  qualified  installer,  service  agency  or 

your gas supplier.

20302353  2/11  Rev. 3

DESIGN

CERTIFIED

CERTIFIED

INSTALLER: Leave this manual with the appliance.

CONSUMER: Retain this manual for future reference.

For use with Approved MHSC 

Fireplace Signature Command 

Models

Electrical  connections  should  be  per-

formed by a qualified electrician, 
The  main  power  supply  must  be  turned 

off before connecting power vent to main 

power  supply  or  before  performing  any 

service.

2353
power vent cover

Содержание 7THPDVS

Страница 1: ...N THIS MANUAL IS NOT FOLLOWED EXACTLY A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE PERSONAL INJURY OR LOSS OF LIFE Homeowner s Installation and Operating Manual FOR YOUR SAFETY Installation...

Страница 2: ...Diagram 8 7THPDVS Power Vent Termination Installation 9 Install Probe Vent Assembly and Venting Pipe 9 Restrictor Plate Installation and Set Up 10 Route Wiring from Power Vent 10 Connect Wiring to Jun...

Страница 3: ...V WDV KSTDV WDVST MDV DVM General Information and Instructions for the DV Power Vent System Model 7THPDVS When using the Power Vent with the KHLDV KSTDV VHLDV or VCFDV Series fireplaces the rear burne...

Страница 4: ...place Fireplace Probe Adapter required Probe Adapter required Probe Adapter required Vent Reducer if Required Vent Reducer if required Vent Re ducer if required 5 Feet Below Bottom of Fire place Maxim...

Страница 5: ...eter regulator assembly 5 m above the meter regulator assy I Clearance to service regulator vent outlet 3 91 cm 3 91 cm J Clearance to nonmechanical air supply inlet 6 15 cm for appliances 10 000 6 15...

Страница 6: ...l sidewalls O 8 2 4 m Min O P 584 15 No of Caps DMin CMax 1 3 914 mm 2 x DActual 2 6 1 8 m 1 x DActual 3 9 2 7 m 2 3 x DActual 4 12 3 7 m 1 2 x DActual DMin of Termination caps x 3 CMax 2 termination...

Страница 7: ...box has a 3 8 standoff on all sides Vent pipes from the fireplace to the DV Power Vent System must refer to fireplace installation instructions for proper clearances 165 6QE 430 mm 1156O 292 mm 4 6QE...

Страница 8: ...ermopile is not used with Power Vent Red Red Black Yellow Power Vent Module Vacuum Switch NOTE Wall switch wires must be connected together FP2793 pv wiring diagram Junction Box Field Supplied 14 2 w...

Страница 9: ...discs are stacked fully open as shown in Fig ure 8 NOTE To achieve the proper flame appearance and igni tion the restrictor disc setting may need to be adjusted by closing any two 2 of the discs depen...

Страница 10: ...ity FP2821 probe vent assy Twist lock Pipe Section Probe Vent Assembly Vacuum Hose Vent Reducer if required Fireplace Starting Collar Figure 10 Probe Vent Assembly FP2821 2 Connect the 14 2 w ground r...

Страница 11: ...rmopile was disconnected NOTE The red wire must connect to the positive red connection The system is polarity sensitive Fig ure 14 5 Connect the black and yellow wires to the two 2 black and yellow sp...

Страница 12: ...power supply cord Plastic Ring Vacuum Hose Power Supply IN and to Power Vent FP2827 Figure 16 SET UP SIGNATURE COMMAND SYSTEM FOR POWER VENT OPERATION The control board program must be reset to operat...

Страница 13: ...r 3 56D3027 7 SS Screw 1 20014369 8 Strain Relief 1 26D0215 9 Electrical Cover 1 20301694 10 8 Screw 2 0052825B 11 Wire Nuts 6 20302355 12 Velcro 1 37D0394 13 Module Power Vent SCS 1 20301934 14 Cable...

Страница 14: ...Vent Pipe 7TDVP36 36 Vent Pipe 30 pack 7TDVP36 30 48 Vent Pipe 7TDVP48 48 Vent Pipe 30 pack 7TDVP48 30 5 x 8 to 4 x 7 Reducer 7TDVP58 Twist lock Elbows 45 Elbow for Vertical Horizontal Offset 7TDVP45...

Страница 15: ...15 DV Power Vent System 20302353...

Страница 16: ...DV Power Vent System 16 20302353 MHSC 149 Cleveland Drive Paris Kentucky 40361 www mhsc com...

Отзывы: