MHSC 400DVBLNV7CE Скачать руководство пользователя страница 1

743000
BLDV 7 cover

DVBL7 Series 
Direct Vent Gas Fireplace

20301763  5/10  Rev. 2

Model: 400DVBLnV7ce

Installation and 
Operating Instructions

 

IF the InForMatIon In theSe InStructIonS 
are  not  FoLLoweD  exactLy,  a  FIre 
or  expLoSIon  May  reSuLt  cauSInG 
property DaMaGe, perSonaL Injury or 
LoSS oF LIFe.
–  Do  not  store  or  use  gasoline  or  other 

flammable vapors and liquids in the vicinity 
of this or any other appliance.

–  what to Do IF you SMeLL GaS
 

•  Do not try to light any appliance.

 

•  Do not touch any electrical switch; do not 

use any phone in your building.

 

•  Immediately call your gas supplier from 

a  neighbor's  phone.  Follow  the  gas 
supplier's instructions.

 

•  If you cannot reach your gas supplier, call 

the fire department.

–  Installation and service must be performed 

by  a  qualified  installer,  service  agency  or 
the gas supplier.

warnInG: Improper installation, adjustment, 
alteration, services or maintenance can cause 
injury or property damage. refer to this manual. 
For  assistance  or  additional  information 
consult a qualified installer, service agency or 
the gas supplier.   
this appliance is only for use with the type of 
gas indicated on the rating plate. this appliance 
is  not  convertible  for  use  with  other  gases, 
unless a certified kit is used. 

warnInGS

Due to hIGh teMperatureS, the appLIance 
ShouLD Be LocateD out oF traFFIc anD 
away FroM FurnIture anD DraperIeS.
chILDren anD aDuLtS ShouLD Be aLerteD 
to  the  haZarDS  oF  hIGh  SurFace 
teMperature anD ShouLD Stay away to 
aVoID BurnS or cLothInG IGnItIon.
younG chILDren ShouLD Be SuperVISeD 
when they are In the SaMe rooM aS the 
appLIance.
cLothInG or other FLaMMaBLe MaterIaL 
ShouLD not Be pLaceD on or near the 
appLIance.
Keep  the  rooM  area  cLear  anD  Free 
FroM coMBuStIBLe MaterIaLS, GaSoLIne, 
anD  other  FLaMMaBLe  VaporS  anD 
LIquIDS.

InStaLLer: Leave this manual with the appliance.
conSuMer: retain this manual for future refer-
ence.

Содержание 400DVBLNV7CE

Страница 1: ...installation adjustment alteration services or maintenance can cause injury or property damage Refer to this manual For assistance or additional information consult a qualified installer service agenc...

Страница 2: ...ectrical Installation 23 Electrical Wiring 23 Glass Removal 24 Remote Wall Switch Installation 25 Operating Instructions Milli Volt 26 Lighting Pilot for the First Time 26 Lighting Pilot 37 Lighting B...

Страница 3: ...ANT SAFETY INFORMATION This fireplace is a vented product This fireplace must be properly installed by a qualified service person The glass door must be properly seated and sealed If this unit is not...

Страница 4: ...een submerged in water 18 Do not operate fireplace if any log is broken 19 Do not use a blower insert heat exchanger insert or any other accessory not approved for use with this fireplace 20 Do not op...

Страница 5: ...ved for closet or recessed installations product SPECIFICATIONS FP2073 BLDV controls Off Pilot On Knob Figure 1 DVBL7 Series Fireplace Millivolt Control shown Hi Lo Knob On Off RS Switch Ignitor FP207...

Страница 6: ...ne Access 400DVBL A 37Z zn 941 mm B 29 737 mm C 40B 1032 mm D 30Z v 768 mm E 17 zn 446 mm F 25ZC zn 656 mm G 31M 810 mm H 31ZB zn 811 mm I 3 76 mm J 1 25 mm K 11C 289 mm L 15 16 24 mm M 15Z 384 mm N 7...

Страница 7: ...for your specific installation requirements Refer to Figure 2 for firebox dimensions The framing headers may rest on the top of the firebox standoffs Do not bring headers below top of standoffs NOTE W...

Страница 8: ...due to heat from appliance Never obstruct the front opening of the fireplace Do not install in the vicinity where gasoline or other flammable liquids may be stored Vent pipe routing Refer to Venting...

Страница 9: ...than wood flooring If installed on carpet or vinyl flooring the appliance shall be installed on a metal wood or noncombustible material panel extending full width and depth of the appliance NOTE All...

Страница 10: ...ction Only noncombustible materials i e brick tile slate steel or other materials with a UL fire rating of Zero may be used to cover the black painted face of the appliance It is permissible to bring...

Страница 11: ...re rigid direct vent components can be used All restrictions clearances and allowanc es that pertain to the rigid piping apply to the flexible venting Flex kits may not be modified Flex kits may be ad...

Страница 12: ...assembly above the meter regulator assembly 5 m above the meter regulator assy I Clearance to service regulator vent outlet 3 91 cm 3 91 cm J Clearance to nonmechanical air supply inlet 6 15 cm for a...

Страница 13: ...a minimum of 3 914 mm below the termination cap 3 All gravity air intakes within 3 914 mm of a termination cap must be a minimum of 1 305 mm below the termination cap General Information Assembling Ve...

Страница 14: ...de wall to the center of the pipe on the fireplace Vertical Dimension From the Floor of Unit to the Center of the Horizontal Vent Pipe eg A eg B T Lock Pipes When using unitized T Lock pipe it is not...

Страница 15: ...on If the vertical rise is 71 2 ft or more only a 1 clearance is needed on top of any horizontal run Vertical sections of this vent system require a minimum of 1 clearance to combustibles on all sides...

Страница 16: ...maintained the horizontal vent length is re duced by 36 914 mm Figures 15 16 This does not apply if the 90 elbows are used to increase or redirect a vertical rise Figure 14 12 Min 3 x 90 Elbows FP117...

Страница 17: ...he 9B x 9B vent opening Step 3 Place fireplace into position Measure the vertical height X required from the base of the flue collars to the center of the wall opening Figure 19 Step 4 Install the uni...

Страница 18: ...02 mm flex vent pipe to the appliance col lar as described on Page 13 Secure the end with the first spring 18C v 476 mm from the flex pipe end to the unit Step 6 Slide the 7 178 mm flex vent pipe over...

Страница 19: ...t will be necessary to ex tend vent pipes out as far as the protruding wall face Figure 24 VERTICAL THROUGH THE ROOF APPLICATION his gas fireplace has been approved for Vertical installations up to 40...

Страница 20: ...is below the shingles Figure 31 8 Install appropriate pipe sections until the venting is above the flashing Figure 31 9 Install storm collar and seal around the pipe 10 Add additional vent lengths fo...

Страница 21: ...ation Vent Storm Collar Flashing Lowest Dis charge Opening Concentric Vent Pipe 1 25 mm Minimum Clearance to Combustibles FP1971 Horizontal Overhang Figure 30 Minimum Chimney Clearance Roof Pitch H fe...

Страница 22: ...necessary gas connections to this appliance CAUTION A manual shutoff valve must be installed upstream of the appliance Union tee and plugged pressure tapping point should be installed upstream of the...

Страница 23: ...gauge over test point Turn unit to high Figure 33 After taking pressure reading be sure and turn captured screw clockwise firmly to reseal Do not over torque Check test points for gas leaks Electrical...

Страница 24: ...amps on bottom of fireplace Figure 34 3 Tilt glass frame out and lift glass frame up until it clears three tabs on top of fireplace 4 Set glass frame aside Each clamp has a quick spring force When rei...

Страница 25: ...length provided NOTE Extended lengths of wire may cause the fireplace not to function properly Longer length of wire is permitted if the wire is made out of larger gauge diameter wire Always check wi...

Страница 26: ...lified service technician Force or attempted repair may result in a fire or explosion D Do not use this appliance if any part of it has been under water Immediately call a qualified service technician...

Страница 27: ...riod of time when the magnet is closed it is possible to start the lighting operation The gas control knob is designed to be operated by hand DO NOT use any tools during this operation Damaged knobs m...

Страница 28: ...This switch allows you to turn on and to turn off the main burner without using the gas valve knob Make sure the button is in the ON position to light the main burner Figure 37 Lighting the burner Dep...

Страница 29: ...th the pin on the burner Also match the cut out on the bottom of the log with the bars on the grate Note When this log is in place pull towards the front 3 Place the right front log 4 over the burner...

Страница 30: ...top right log 2 by resting it over the upper right log and the rear log This log will curve to the middle as it rests over the rear log final installation LG613 DVBL upper rear log LG612 DVBL left fr...

Страница 31: ...urner Flame The flames from the burner should be visually checked as soon as the heater is installed and periodically during normal operation In normal operation at full rate and after operating for a...

Страница 32: ...s may be used Handle glass door with care to avoid striking or scratching it on hard objects To clean glass door follow Glass Removal procedure outlined in the Final Installation section Film deposit...

Страница 33: ...hat the thermocouple connec tion at the gas valve is fully inserted and tight Disconnect the thermocouple from the valve place one millivolt lead wire on the tip of the thermocouple and the other mete...

Страница 34: ...ximum flame impingement on thermocouple A Check for flue product leak Replace defective pipe section B Check horizontal venting piping is running upward 1 4 per foot Do not run the pipe level or downw...

Страница 35: ...Junction Box Assy not shown 1 26D2128K 2 Sheet Metal Base 1 74D0514 3 Glass Frame Assy 1 74D0096K 4 Control Cover 1 74D0038K Accessories Field Installed Options 5 Decorative Mesh Glass Cover 1 BLDV40...

Страница 36: ...20301763 36 DVBL7 Series Gas Fireplace REPLACEMENT PARTS Standing Pilot Millivolt control 1 2C 2I 2T 2 4 5 3 7 8 6 9 10 11 12 13 1763 DVBL7 millivolt parts...

Страница 37: ...lacement Thermopile 1 37D1068 37D1068 3 Burner Tube 1 74D0049K 74D0049K 4 Rocker Switch 1 41D0048 41D0048 5 Piezo Igniter 1 14D0503 14D0503 6 Injector 1 20H3147 33D5039 7 Burner Assy 1 74D0098K 74D009...

Страница 38: ...LACEMENT PARTS 1 6 5 2 3 4 743000 BLDV log parts Ref Description Qty 400DVBL 1 Rear Log 1 1 74D0059 2 Top Right Log 2 1 74D0060 3 Front Upper Log 3 1 74D0061 4 Right Front Log 4 1 74D0062 5 Left Front...

Страница 39: ...Pipe 30 pack 47TL36 30 48 Vent Pipe 47TL48 48 Vent Pipe 30 pack 47TL48 30 T Lock Elbows 45 Elbow for Vertical Horizontal Offset 47TLE45 45 Elbow for Vertical Offsets 8 pack 47TLE45 8 90 Elbow for Ver...

Страница 40: ...ent Length 47TL1218 35 64 Adjustable Vent Length 47TL3564 8 Vent Pipe 4 pack 47TL8 4 12 Vent Pipe 4 pack 47TL12 4 24 Vent Pipe 4 pack 47TL24 4 36 Vent Pipe 47TL36 36 Vent Pipe 30 pack 47TL36 30 48 Ven...

Страница 41: ...20301763 41 DVBL7 Series Gas Fireplace...

Страница 42: ...20301763 42 DVBL7 Series Gas Fireplace...

Страница 43: ...fetime Warranty will also be void if the appliance is not operated and maintained according to the operating instructions supplied with the appliance and does not extend to 1 firebox burner assembly d...

Страница 44: ...MHSC 149 Cleveland Drive Paris Kentucky 40361 www mhsc com...

Отзывы: