7.12.
Additional equipment
7.12.1.
Flash Cure Units
Flash cure units may be installed into
either an empty station or a print
station. The flash cure unit must be
powered by a separate supply, which
should comply with the electrical data
supplied by the manufacturer
(see
data sheet for flash cure units).
To
control the unit the dryer must be
connected with the dryer connector of
the station.
Procedure for the installation of a flash cure unit into a print station
An empty/blank screen frame (without mesh) should be loaded in the position of a
normal screen in order to push and hold the screen holders away from the heated area
to prevent any damage. Move the squeegee carriage backward to its rear end position
before installing the flash cure unit into the print station. Subsequently, the electrical
supply and data lead should be connected.
When connecting the dryer with the dryer connector of the station
the unit will be identified automatically and the print function of the
station will be switched off. Be sure that every dryer which is installed
into a print station is connected with the dryer connector.
The pallets are only warranted to withstand temperatures of up to a
maximum of 150° C. Exceeding this temperature will result in the
cancellation of warranty for the pallets.
When connecting the flash cure unit make absolutely sure to keep
the all cables away from any moving parts (especially the
tables/moving pallets etc). Failure to do so may result in damage to
the cable along with serious electrical damage to the flash cure unit
and machinery.