background image

BASIC SAFTY

Mountain High Oxygen systems are designed to contain and deliver pure oxygen for the
purpose of supplemental breathing as needed for exposure to high altitudes.  They are not
intended for medical or underwater use.   Pure oxygen is a highly oxidizing gas in nature and
vigorously accelerates combustion.  It can provide a catalyst for spontaneous combustion if
not used properly and with caution.  DO NOT use any type of oil or grease on any of the
fittings, valves or cylinders.  DO NOT use the system while smoking or near an open flame.

NOTICE

The EDS model "A" operates with a standard aviator's nasal cannula for single person flight
operations up to 17,999 ft. or a face mask for flight operations over 17,999 ft. and up to
30,000 ft.  Both of these items are included with each EDS kit.   Several EDS units can share
a single cylinder and primary reducing regulator for multi-place operations.   Pilots should
refer to FAR 23.1447 to see if any restrictions apply for their use of cannula type breathing
devices in the operation of their aircraft.  Information and data in the field of flight
physiology is constantly changing and updated.  Therefore, Mountain High E&S Co. reserves
the right to correct and enhance this manual and associated documentation at any time
without notice.

Operation Manual

for the

E D S

Electronic Oxygen Delivery System

Analog Computer Model A-1

R 3.7

Aviation Oxygen
Management Systems

625 SE Salmon Ave, Redmond, OR. 97756

Tel: 541-923-4100    Fax: 541-923-4141

MH

Содержание EDS A-1

Страница 1: ...erations up to 17 999 ft or a face mask for flight operations over 17 999 ft and up to 30 000 ft Both of these items are included with each EDS kit Several EDS units can share a single cylinder and pr...

Страница 2: ...yed mode will arm the EDS unit to delay delivering oxygen until it is at a pressure altitude of 10 000 ft This is suitable for day time fight operations The power ON OFF switch makes connects and brea...

Страница 3: ...e lapse rate curve that starts at sea level and lowers towards a partial pressure representing some very high altitude i e 100 000 ft The spa curve assumes that at sea level the barometric pressure is...

Страница 4: ...ylinder The low pressure service line c is a high quality polyurethane line that is kink proof and flexible under varying temperatures The cannula and service line connects to the EDS unit via Quick C...

Страница 5: ...ethane line without pushing in the collar It will damage the connector See figures below DO NOT ATTEMPT TO REMOVE REGULATOR FROM CYLINDER WHILE UNDER PRESSURE Doing so will destroy the O ring on the r...

Страница 6: ...have their own nasal cannula and face mask In addition replacement of the nasal cannula should be done if it has become soiled or damaged in any way The flow fault alarm will respond to the following...

Страница 7: ...the inside diameter of the 6mm outlet tube on the EDS unit 3 With the EDS unit on and the battery test button depressed turn on the cylinder valve slowly to allow gas to flow backwards through the ED...

Страница 8: ...nto one standard cannula This allows the pilot to simply throw an on off switch to bypass the EDS unit then having the ability to adjust the flowmeter for the altitude to economize on oxygen usage Bec...

Страница 9: ...unit The EDS EPS External Power Supply input jack and plug EDS EPS EDS unit 10 26 VDC input strip The EDS EPS with internal noise and glitch filter unit can operate up to six EDS units External Batter...

Страница 10: ...C Nom 25 RH 25 C Max 100 RH 50 C near condensing Vibration Random vibration 5 to 500 Hz 15 minutes per axis 2 5 g rms sin wave Operating pressure range pressure altitude Min 3 4 psia 25 C appx 30 000...

Страница 11: ...by Mt High E S Co at a nominal charge Before this warrantee can be valid Mountain High Equipment Supply Co must have your owners guarantee registration form properly filled out and in our files Mount...

Отзывы: