MH E-Z Breathe II Boom Cannula

The MH “

E-Z Breathe II

 Boom Cannula

 is manufactured to the highest standards in a 

medical ISO and CE certified facility.  The MH E-Z Breathe II

 Boom Cannula is warranted 

to be free of defects of materials and workmanship for a period of one year. This warranty is 

limited to replacement of the defective part. This warranty specifically excludes consequential 

damages including but not limited to those suffered as a result of improper use, application, 

installation or failure to monitor oxygen delivery and blood oxygen saturation levels

.

The MH E-Z Breathe II™ Boom Cannula kit is supplied with the following components:

- Qty-1 Instruction Sheet
- Qty-1 E-Z Breathe II Cannula Boom.   (MH Item Number 00VEN-0071-00)  1
- Qty-1 MH Universal Ball Mount.  

 (MH Item Number 00VEN-0072-01)  

Not Shown

- Qty-2 3M Super Adhesive Pads  

 (MH Item Number 00VEN-0073-02) 

Not Shown 

- Qty-1 Square Standoff  

 

 (MH Item Number 09052-0802-04)   

- Qty-1 Spacer  

 

                (MH Item Number 09054-0803-09)   

- Qty-1 Thumb Screw 

 

 (MH Item Number 09120-0810-03)

- Qty-1 Replacement Cannula 

 (MH Item Number 00VEN-0074-01)

Mountain High Equipment & Supply Company 

 2244 Airport Way 

Suite 100 

Redmond OR 

97756 

 

   NOTE: 

The MH E-Z Breathe II

 Boom Cannula is not to be used above 

18,000 feet msl!  

(Consult CFR14, FAR 23.1447 for more information). 

To ensure safety and avoid hypoxia at high altitudes, verification of blood oxygen 

percentage with a Pulse Oximeter is recommended. 

Do not discard the nose pieces! 

They are designed as re-useables. Simply wash in clean warm soapy water, rinse, dry 

and re-use ... When not needed, rotate the arm up and out of the way, or loosen the 

thumbscrew and carefully un-snap it from the mounting ball and store in a bag. 

Rev 11/2013

5I000-1092-00

NOTE: 

 

Additional E-Z Breathe II

 components can be ordered from MH. 

Call 800-468-8185 or E-mail [email protected]

LIMITED WARRANTY

The MH E-Z Breathe II

 Boom Cannula is designed for comfort, ease of 

use and serviceability.  It adjusts easily and can be positioned to suit 

almost everyone comfortably.  The MH E-Z Breathe II

 Boom Cannula 

is compatible with all MH oxygen delivery systems and many devices 

available by other manufacturers. Consult with MH before using as such.

Pilots who have purchased the MH E-Z Breathe II

 Boom Cannula 

and plan to fly Class A airspace (above 18,000 feet msl) have also 
chosen the MH Alps Mic Face Mask. Utilizing a  “noise reducing” 
microphone that is built into the MH Alps Mask, both your commu-
nication and oxygen Class A requirements can be satisfied. Masks 
are available in small, medium and large sizes.  Call 800-468-8185 
or E-mail [email protected] for additional information.

Aviation Oxygen Systems

MH

5

3

4

2

Telephone: 541-923-4100     
Toll-Free 1-800-468-8185
Fax: 541-923-4141 
E-Mail: [email protected]
Web: www.MHoxygen.com 

NOTE:

 If used with a Constant-Flow Oxygen System, a Non-Conserving or Face Mask 

setting must be used. The E-Z Breathe II

 Cannula is not a conserving cannula. 