Получите руководство пользователя для продукта MH Corbin Connect: ITS бесплатно с нашего веб-сайта. Просто загрузите его с manualshive.com. Наши подробные инструкции помогут вам с легкостью освоить этот продукт.
MH Corbin Connect:ITS
User Manual
Version 3.6
September 21, 2020
MH Corbin
6077 Frantz Rd Ste 203
Dublin OH 43017
800-380-1718
https://mhcorbin.com
Страница 1: ...MH Corbin Connect ITS User Manual Version 3 6 September 21 2020 MH Corbin 6077 Frantz Rd Ste 203 Dublin OH 43017 800 380 1718 https mhcorbin com...
Страница 2: ...oftware remains in full force and effect Should the license terminate for any reason it is your responsibility to certify in writing to MH Corbin that all copies and partial copies of the documentatio...
Страница 3: ...rs 9 Connect ITS DIN 9 Front Panel 9 Display Button Modes 10 Front Panel LEDs 10 Bottom Panel Connectors 11 Antenna Connectors 11 Exploded View of RS485 GPIO Pinout 12 RS232 Connectors 13 USB Connecto...
Страница 4: ...Reset Buttons 26 System Info 27 Setup IP Page 27 Single NIC Mode 27 Dual NICs and Bridged Mode 27 Nameserver 28 DHCP 28 MAC Address Firmware Version Refresh Date Stamp 28 Static IP 28 Setup Logging Pa...
Страница 5: ...ng 39 Step 7 Change Default Route Step 7 40 Frequently used Modem APN Strings 40 Setup Scripts Page 40 Creating Scripts 41 Applications 43 Rest Api s 43 Lidar 44 Lidar Tab 44 Appendix A Sensor Channel...
Страница 6: ...HD125 Periodic 50 Appendix B Database Schema 51 Change Log 53...
Страница 7: ...op of the Connect ITS down swing the bottom part of the mount inwards toward the rail Power Hook Up Power is supplied through a 12VDC or 24VDC power supply or from a 12VDC or 24VDC battery Power is pr...
Страница 8: ...l data connections RS232 1 2 Connector for RS232 sensors USB 1 2 Connector for USB sensors Cell Antenna connector for internal cellular modem GPS Antenna connector for internal cellular GPS VX Antenna...
Страница 9: ...ower Input 12VDC 2 5 amp size 2 1mm X 5 5mm Fuse Holder 2 5 amp Slow Blow fuse Connect ITS DIN Front Panel Connect ITS DIN Front Panel LCD Screen Displays unit information IP address IP Mode CPU Temp...
Страница 10: ...__________ Display Button Modes Display Button Modes First IP Address for Eth 1 CPU Temperature shown as Celsius Can be changed to Fahrenheit in Setup IP Address Type shown as Static Can be changed to...
Страница 11: ...isk activity SBC Lights green when the internal computer has powered up PWR Lights green when the unit is receiving power from the backplane HBT Flashes blue when unit is operating normally Bottom Pan...
Страница 12: ...nout ttyXRO ttyXR1 ttyXR2 and ttyXR3 Sensor Input connector for sensors that utilize the RS485 serial data connections AI1 and AI2 Analog inputs 0 5 volts DO1 and DO2 Digital Outputs 0 5 volts 5V Regu...
Страница 13: ...nd ttyS1 Sensor Input connector for sensors that utilize the RS232 serial data connections USB Connectors USB Connectors USB connectors for sensors that utilize USB data connections Power Connector Po...
Страница 14: ...___________________________ 14 ___________________________ Ethernet Ports Dual ethernet ports with bridging capability Display and Audio Connectors Display and Audio reserved for future use...
Страница 15: ...______________________ Setup Modem Physical Modem Top View circled in orange is the modem number for Modem drop down Modem Bottom View Modem Mounts to Board with Antenna Connectors Facing Inwards Wher...
Страница 16: ...dded on to an existing RWIS system or it can be used with our Connect ITS product The Connect ITS line uses a VXMS Receiver Radio to communicate with the VX 21 In North America the module uses a 900 M...
Страница 17: ...cable Ensure that the laptop is set to use a static IP which is in the same Subnet as the Connect ITS s current IP address First IP Address on LCD Screen for Eth 1 Port Open a web browser and navigate...
Страница 18: ...________________ 18 ___________________________ Control Page The default Control page shows the system status The digital outputs of the Connect ITS can be toggled on or off using the buttons in the r...
Страница 19: ...longitude and altitude information Ping Remote Host By entering a valid IP address of a host machine we can ensure that a connection between that host and the Connect ITS is able to ping properly SNM...
Страница 20: ...h the Intellizone application A guide has been provided in the following table V2I RSU Parameters Pre FW 1 0 42 RSU Type Compatible with 4 1 AM spec unless otherwise specified Siemens ESCoS SNMP Cohda...
Страница 21: ...ard to Data sent is encoded XML Example 192 168 200 5 8990 192 168 200 22 9191 Forward Endpoint Websocket use Examples ws 192 168 200 5 vru ws 192 168 200 5 9041 TX Mode Transmission Mode Values based...
Страница 22: ...request Speak with an MH Corbin consultant to set up a demonstration as well as licensing information In alpha version FW 1 0 42 this feature has been moved and extended to a subtab of the Setup Menu...
Страница 23: ...8086 Database Name Name of the database Example connect_its_vru Telegraf Interval Seconds The telegraf agent broadcasts are configurable in seconds On a modem depending on what is being monitored a h...
Страница 24: ...egraf temp stats This monitors the stats of the Connect ITS cpu temperatures Metiri Application Snapshot Overview Figure 1 Metiri Intellizone Data for Pedestrian Collision Wrong Way Queue Work zone Al...
Страница 25: ...e sections to focus only on the data you need at that moment Figure 4 Example of a Threshold Alert that can Trigger multiple forms of output including email Figure 5 Example of Corresponding Alert Pan...
Страница 26: ...ct configuration To do so once you are happy with your Connect ITS setup simply click the Generate button Once the backup is complete you will be presented with a success message And you will see that...
Страница 27: ...Connect ITS supports two IPv4 network ports through DHCP and Static addressing From the factory the unit comes with a static IP configured Single NIC Mode By default only the primary NIC interface se...
Страница 28: ...either an organizations internal DNS servers or a public DNS server like Googles famous 8 8 8 8 DHCP To allow a host system to assign an IP address automatically select the Assign automatically with...
Страница 29: ...here date is the date of the log entry in YYYY MM DD format time is the 24 hour time of the log entry in HHMM SS ms format module is the name of the module where the log entry originated from type is...
Страница 30: ...r logging allows the user to quickly zero in on items that are causing application errors Setup Password Page Use this form if you want to change the default passwords for the Control and Setup page M...
Страница 31: ...as Setup Setup Firmware This page allows users to check Connect ITS and its hardware components firmware versions as well as to install Connect ITS firmware updates Once the new firmware image has bee...
Страница 32: ...page Failure of firmware To correct this problem utilize the following process Reboot the box using the Reboot Device option on the Setup screen covered earlier in this manual Try reinstalling the fir...
Страница 33: ...use the main MH Corbin phone number for assistance Rolling Firmware Back If it is determined that a firmware update has caused problems it is possible to roll the firmware back to a former version by...
Страница 34: ...at the Connect ITS can communicate with them and collect data Sensors Connect ITS can be configured for a variety of different sensors A current list is included at the beginning of the manual The ITS...
Страница 35: ...g interval History Specifies number of hours thatConnect ITS will keep collected sensor data for Any sensor data that is older than the specified value will be erased A value of 24 indicates to hold o...
Страница 36: ...a Device ID per device with up to 9 different device ID s available Not all sensors require this value but if the sensor does require an ID assignment and this field is set incorrectly the Connect IT...
Страница 37: ...nfigured ITS sensors will be listed in the Configured sensors form Please use corresponding Del button to remove the sensor The page will ask to confirm sensor removal and will delete specified sensor...
Страница 38: ...ns To change just select the serial port the modem is using and click Submit NOTE On a Connect ITS DIN the default port should be dev ttyUSB4 You only need to change this setting as directed by MH Cor...
Страница 39: ...Step 4 PPPo Adapters Show prints the network interfaces file Add sets the network adapter for the modem and reboots the device If there is a very long delay 5mins in booting the unit verify that the...
Страница 40: ...nds on either the customer or who purchased the SIM card or where the SIM card was ordered NIMBLELINK DIGIKEY NIMBLINK GW12 VZWENTP PENNDOT PADOTBP GW3 VZWENTP CALTRANS DOT CT7MOBILE5 DOT CA GOV BEAUF...
Страница 41: ...ubject subject 17 self logger info body body 18 19 msg MIMEText body 20 msg Subject subject 21 msg From mail_from 22 msg To join mail_to 23 24 try 25 s smtplib SMTP self mail_server self mail_port 26...
Страница 42: ...stop the script from being executed automatically To remove a script click the Remove button Clicking the Code link located next to the name of the script will load the script into the editor window...
Страница 43: ...i Rest Api s The Connect ITS has Restful API s created for different events depending on the scenario and licensing Currently the API s authenticate using Basic Access Authentication Some are listed i...
Страница 44: ...nnect ITS only one device can be attached currently Application Wrong Way Detection and are licensed a new tab will appear in the Connect ITS menu This offers a view of the lidar setup and is useful f...
Страница 45: ...Lufft WS100UMB Channel Name Channel Measurement Type Unit Min Max Precipitation Quantity Differential 625 mm N A N A Precipitation Type 700 Preciptiation Type 0 No Precip 60 Liquid Precip 70 Solid Pre...
Страница 46: ...ature 100 Celcius 50 0 60 0 Dew Point Temperature 110 Celcius 50 0 60 0 Relative Humidity 200 0 0 100 0 Absolute Air Pressure 300 hPa 300 1200 Precipitation Type 700 Preciptiation Type 0 No Precip 60...
Страница 47: ...Temperature 110 Celcius 50 0 60 0 Relative Humidity 200 0 0 100 0 Absolute Air Pressure 300 hPa 300 1200 Wind Speed 400 m s 0 75 Wind Direction Fast 501 degrees 0 359 9 Compass 510 degrees 0 359 Preci...
Страница 48: ...1UMB Channel Name Channel Unit Min Max Road Temperatures 100 Celcius 40 0 70 0 Freezing Temperatures 110 Freezing Temp NaCl 40 0 0 Water Film Height 600 m micrometer 0 0 2000 0 Ice Layer Thickness 601...
Страница 49: ...6 0 Snow Height 612 mm 0 0 50 Ice Percentage 800 0 0 100 0 Friction 820 N A 0 0 1 0 Road Condition 900 0 Dry 1 Damp 2 Wet 3 Ice Covered 4 Snow Ice Covered 5 Chemically Wet 6 Water Ice 8 Snow Covered 9...
Страница 50: ...60 0 DST Status 61 N A 00 99 Surface Status 66 21001 WRS N A N A Grip 68 21002 N A 00 99 DSC Status 71 N A 00 99 Water 72 mm 00 00 99 00 Ice 73 mm 00 00 99 00 Snow 74 mm 00 00 99 00 Wavetronix HD HD12...
Страница 51: ...g 1024 COLLATE pg_catalog default ipaddress character varying 1024 COLLATE pg_catalog default ipport character varying 1024 COLLATE pg_catalog default channelinfo character varying 1024 COLLATE pg_cat...
Страница 52: ..._____________ channel CONSTRAINT sensordata_sensorid_fkey FOREIGN KEY sensorid REFERENCES public sensor id MATCH SIMPLE ON UPDATE NO ACTION ON DELETE NO ACTION WITH OIDS FALSE TABLESPACE pg_default AL...
Страница 53: ...m views correct sim card installation antenna locations and board placement Renamed to indicate Hardware Manual Added VX21 Installation and information 2 20 2020 Merging in of Software Changelog Versi...
Страница 54: ...ion Setup Logging add error logging information Setup Units Time add NTP sync option Setup Sensors Page add new network sensor guide Setup Scripts update product screenshot Applications section add in...