14 – Sectional door operator STA 1 / Rev. D 0.3
Type (E / KU / KE):
STA 1-11-19
STAC 1-11-19
STA 1-10-24
STAC 1-10-24
STA 1-13-15
STAC 1-13-15
STA 1-12-19
STAC 1-12-19
STA 1-11-24
STAC 1-11-24
STA 1-10-30
STAC 1-10-30
Driving torque (Nm):
110
100
130
120
110
100
Static holding torque (Nm):
600
600
600
600
600
600
Driving motor speed (min -1):
19
24
15
19
24
30
Motor output (kw):
0.37
0.37
0.55
0.55
0.55
0.55
Operating voltage (V):
230 / 400 / 3~
230 / 400 / 3~
230 / 400 / 3~
230 / 400 / 3~
230 / 400 / 3~
230 / 400 / 3~
Mains frequency Hz:
50
50
50
50
50
50
Control voltage: (V):
24
24
24
24
24
24
Nominal motor current (A):
3.5 / 2.0
3.5 / 2.0
3.1 / 1.8
4.1 / 2.4
4.1 / 2.4
3.5 / 2.0
Maximum no. of operating
cycles per hour *:
20
20
20
20
20
20
Fuse protection on site (A):
10,0
10,0
10,0
10,0
10,0
10,0
Protection type (IP)
54
54
54
54
54
54
Temperature range (°C)**:
-20 / +60
-20 / +60
-20 / +60
-20 / +60
-20 / +60
-20 / +60
Continuous sound pressure level
(dB (A)):
< 70
< 70
< 70
< 70
< 70
< 70
Weight per piece (kg):
15
15
15
15
15
15
Maximum number of
revolutions of driven shaft:
20
20
20
20
20
20
Hollow shaft (mm):
25.4
25.4
25.4
25.4
25.4
25.4
*
1 cycle = 1 complete door movement (open and then close the door).
The values given assume an even distribution.
**
Temperature ranges < -5 °C: Type of oil and electric heater on request.
9. Technical data