13. Technical data
13.1
13.1 Mechanical and electrical data
Mechanical and electrical data
Housing dimensions
(W x H x D):
215 x 275 x 190 mm (FU-I 0.75 kW)
245 x 455 x 190 mm ( FU-E 0.75 kW,
FU-E 1.5 kW / 400V / 3~
FU-E 2.2 kW / 400V / 3~)
260 x 550 x 245 mm ( FU-E 1.5 kW / 230V / 1~
FU-E 3.0 kW / 400V / 3~
FU-E 4.0 kW / 400V / 3~)
Installation:
Fix vertically to the wall
at a minimum height of 1,100 mm
Power supply via
L1, N, PE:
230V/1~ , 50/60Hz (0.75 kW / 1.5 kW)
L1, L2, L3, N, PE:
400V/3~ , 50/60Hz (1.5 kW / 2.2 kW / 3.0 kW
/ 4.0 kW)
Maximum rated
motor current:
230V/1~ / 0.75 kW
–> 4.1 A
230V/1~ / 1.5 kW
–> 6.7 A
400V/3~ / 1.5 kW
–> 4.1 A
400V/3~ / 2.2 kW
–> 5.6 A
400V/3~ / 3.0 kW
–> 7.3 A
400V/3~ / 4.0 kW
–> 8.8 A
Fuse protection:
230V/1~ / 0.75 kW
–> 10 A
230V/1~ / 1.5 kW
–> 16 A
400V/3~ / 1.5 kW
–> 10 A
400V/3~ / 2.2 kW
–> 10 A
400V/3~ / 3.0 kW
–> 10 A
400V/3~ / 4.0 kW
–> 16 A
Fuse elements with K-type characteristic.
If supplied with three-phase current, only blocks
of three automatic circuit-breakers must be
used.
Controller internal
consumption:
max. 750 mA
Control voltage:
24 V
DC
, max. 500 mA; protected by
automatically resetting fuse for external sensors
Controller inputs:
24 V
DC
, all inputs are to be connected
potential-free.
Minimum signal duration for input controller
command >100 ms.
Controller outputs:
24 V
DC
, max. 500 mA.
Safety circuit /
emergency stop:
All inputs must be connected potential-free;
with an interruption of the safety chain, no
further electrical movement of the drive is
possible, even with dead man’s switching.
Light barrier
(Protection level D):
If the light barrier is used as a protection
system according to level D, its function must
be checked regularly and within 6 months as a
minimum.
If this is a self-testing system, this requirement
does not apply.
Safety input with
resistance evaluation
Performance Level C, cat.2
for safety-related components with 8.2 kΩ
terminal resistance
Display (LCD):
Only an original LCD monitor from MFZ may
be used.
Relay outputs:
If inductive loads are to be switched (e.g.
Additional relays or brakes), these must be
equipped with corresponding interference
suppression measures (e.g. Free-wheeling
diodes, varistors, RC elements). Work contact
potential-free; min. 10 mA; max. 230 V
AC
/ 4A.
Contacts that have been used for power
switching can no longer be used for switching
low currents.
Temperature range:
Operation: -10°C to +45°C
Storage:
-25°C to +70°C
Humidity:
Up to 80% non-condensing.
Vibrations:
Low-vibration mounting, e. g. on a masonry
wall.
Protection grade
IP 65
Weight
approx. 1.8 kg