MFJ-816 Instruction

Thank you for purchasing the MFJ-816 HF SWR 

Wattmeter. The MFJ-816 

measures

forward power, reflected power and SWR. The 

wattmeter measures 

power on two

scales, 30 

watts and 300 watts. The MFJ-816 

is usable from 

1.8 MHz thru 

30 MHz.

Installation

1.

Connect of a coax cable from the transmitter to the TRANSMITTER 

Coax

connector of the MFJ-816.

2. Connect the antenna cable to the ANTENNA coax connector of the MFJ-816.

Operation 1. To Measure SWR:

Set the  push  button to the FWD/SET position. Transmit a continuous  carrier and
set the SWR/POWER control for a full scale deflection on the  meter.  Set the
push button to the REF/SWR position and read the SWR.

Note: The SWR sensitivity must be reset when power level is changed.

This

will maintain and accurate SWR reading.

2. To Measure Power

300 Watt Scale

Set the SWR/POWER control to the 300 mark. Set  the_ push button  to  the
FWD/SET position to read forward power and to REF/SWR to read reflected
power. This scale reads maximum of 300 watts.

3 0  Watt Scale

The 30 watt scale can be used to measure forward and reflected power up to 30
watts. To measure forward power, set the push button  to  the FWD/SET
position. To measure reflected power, set the push button to the REF/SWR
position.

The 30 Watts position is not calibrated at the factory because of variations
due to components tolerance. To calibrate the 30 watt scale, follow this
procedure: Set the push button to the FWD/SET position and the SWR/POWER
control to 300. Transmit a continuous carrier and not the power level on the
300 watt scale. Power from the transmitter should be set as close to 30
watts as possible without exceeding 30 watts. This will give the most
accurate calibration. Now rotate the SWR/POWER control so that the reading on
the 30 watt scale is the same as what was noted on the 300 watt scale. Mark
the dial for the calibrated 30 watt range.