background image

General 
SEQ-02 is a programmable step-sequencer in module-format that allows creating synthesizer-
sequences  as  well  as  rhythmic  sequences.  It  offers  twelve  tracks  that  may  either  control  six 
synthesizer  voices  (or  6  drum-tracks)  with  six  CV-tracks  or  up  to  twelve  trigger-tracks. 
Finally,  SEQ-02  can  also  generate  up  to  twelve  CV-sequences  at  the  same  time  –  all  on 
separate outputs. 
The  SEQ-02  has  four  operating  modes  that  differ  in  the  number  of  available  tracks  and 
outputs. Each mode has its proprietary memory area, so that the sequences are preserved when 
switching operating modes. 
 
Set-up 
SEQ-02  is  fully  compatible  to  Doepfer’s  A-100  modular  system  -  in  size,  bus-power  and 
CV/Gate  voltage.  Connect  the  10-pin  cable  to  a  corresponding  16-pin  jack  on  the  Doepfer 
mainframe bus (or on the MIDI/CV circuit-board). Supply voltage needs to be +/- 12 volts, 5-
volt  connections  are  not  required.  The  wattage  is  +60  mA/-  10  mA,  the  module  size  20  TE 
(Teileinheiten) = 101.3 mm. 
 
ATTENTION:  Please,  check  for  correct  polarity!  The  colored  side  of  the  connector-cable 
needs to point downwards, so that the cable is not twisted. 

 

Selecting the operating mode 
The  current  active  operating  mode  is  displayed  by  the  step-LEDs  9-12,  when  pressing  and 
holding both REC and SEQUENCE for at least one second.  

  

Step 09 = Mode 1 

6 CV- and 6 gate-tracks, each CV-track is paired with a corresponding 
gate-track.   

Step 10 = Mode 2 

6 CV- und 6 gate-tracks, individual programming (unpaired) 

Step 11 = Mode 3 

12 CV-tracks with individual programming 

Step 12 = Mode 4 

12 gate-tracks with individual programming 

  

To  change  the  operating  mode,  press  and  hold  REC  and  SEQUENCE  plus  the  respective 
step-button 9 to 12. 
 
Selecting the sequence  
Select  between  the  16  memorized  sequences  by  pressing  SEQUENCE  and  one  of  the  step-
buttons. Do not hold the SEQUENCE button! The selection mode is indicated by a lit LED on 
top of the SEQUENCE button. Now, press the respective step-button. When stopped, the new 
sequence  will  immediately  be  loaded.  During  playback  the  selected  sequence  will  be  started 
after  the  active  sequence  is  completed.  Adjacent  sequences  can  be  called  up  by  external 
triggers at inputs SE and SEQUENCE –. 
 
Start/Stop 
Use the Start/Stop button to start a sequence after selection. A second push of the button will 
stop the sequence. This function can also be controlled by a trigger-signal at Start/Stop. This 
jack  can  be  used  as  input  (min.  +5  volts)  as  well  as  output  (+5  volts).  The  first  incoming 
trigger will start the sequencer, the next will stop it.  
 

A, A/B, B  
This function selects if a sequence will play sequence part A, part B or AB alternating (which 
equals two bars length). 
Tip:  When  programming  a  two-bar-sequence  it  is  often  more  comfortable  to  complete 
programming  part  A first, followed by part B. By this, you avoid a constant changing of the 
step-LEDs. 
 
Sequencer-tracks 
The turn-switch on the module’s left selects the sequencer-track to be programmed/edited. The 
tracks are coded CG1 to CG12 with the following functions depending on the selected mode: 
 

Mode 1+2 

CG1…CG6 = CV1…CV6 

 

 

CG7...CG12 = Gate7...Gate12 

 

 

(CV1 corresponds to Gate7, CV2 to Gate8 etc.) 

 

Mode 3 

CG1…CG12 = CV1…CV12 

 

Mode 4 

CG1…CG12 = Gate1…Gate12 

 
Steps
  
The steps in a track can only be set while the sequence is running, not while the sequencer is 
stopped. There are two ways to set the steps in a track: 
 
1:  To  program  a  single  step,  press  the  respective  step-button  and  enter  the  value  using  the 
DATA-knob. Press the DATA-knob to erase the step. If you erase part of a tied note, the other 
part will remain as a “new” note. 
 
2:  To  set  multiple  steps  at  the  same  time  (useful  for  CV-voltages  in  modes  2  and  3),  press 
REC  followed  by  the  first  respective  step-button.  Next,  press  the  second  step-button  and 
release both REC- and step-buttons. Now, you can set all steps between the first and second 
step simultaneously. 
 
Programming is slightly different, according to the mode selected. 
Mode 1: After selecting the step(s), use the DATA-knob to define a control-voltage for tracks 
CG1...CG6  (0...5  volts  following  the  1  volt/octave  standard).  The  corresponding  gate 
information (9 volts) will automatically be set on the paired gate-tracks. 
Mode  2:  Set  control  voltages  as  described  in  Mode  1.  The  gate-tracks  CG7...CG12  are  set 
separately, using the DATA-knob. Adjustment ranges from 0 to approx. 9 volts. 
Mode 3: After selecting the step(s), use the DATA-knob to define a control-voltage for tracks 
CG1...CG12 (0...9 volts following the 1 volt/octave standard). 
Mode  4:
  After  selecting  the  step(s),  use  the  DATA-knob  to  define  a  gate-voltage  for  tracks 
CG1...CG12 (0...9 volts) 
 
Hint: CV- and gate-voltages differ: CV-voltage lasts for a full 16th note while a gate-voltage 
is a combination of 1/32nd ON and 1/32nd OFF. 

Отзывы: