45
Fault correction
Fault
Cause
Remedy
Battery indicator on the
operating module does
not light up after the
switch-on.
Circuit breaker is defective
or not correctly inserted.
Replace defective circuit
breaker or clean contacts
and insert correctly.
Plug connection of the
power supply without
contact.
Check the plug connec-
tions.
The battery gauge blinks
after the switch-on.
One or both of the drive
motors are switched to
push mode.
Move the selection lever
for the drive/push mode
into the drive mode posi-
tion on both sides.
Plug connection at one of
the drives without contact.
Check the plug connec-
tions.
Malfunction in the elec-
tronics.
Have it repaired by the
specialist workshop. (Push
mode)
Selection lever in driving
mode position.
Not listed faults.
View <
error diagnostics
>
in the operating manual
for the operating module.
Lighting not active.
LED-lamp defective.
Let it be repaired or re-
placed by a specialist
workshop.
Lighting fuse or drive elec-
tronics defective.
Let it be repaired or re-
placed by a specialist
workshop.