Electrical Symbol 

 

Extremely  dangerous

The  operators  must  keep  to  the  safety 

rules strictly; otherwise, electric shock will result in death or injury. 

 

 

Dangerous

The operators must keep to the safety rules strictly, 

otherwise, electric shock will result in will result in death or injury. 

 

 

Warning

The  operators  must  keep  to  the  safety  rules  strictly, 

otherwise, personal injury or equipment damage will occur.. 

 

 

Double insulation

 

 

Alternating current (AC) 

 

Direct current (DC)

 

 

III

Series Model 

Model 

Range 

Coil Diameter 

Coil Length 

MEWOI9000G 

AC 0.00A

20000A 

φ

300mm(300G) 

1000mm 

MEWOI9000GB 

AC 0.00A

6000A 

φ

200mm(200G) 

630mm 

 

IV. Technical Specifications 

Functions

 

Measuring  AC leakage current  and  AC current,  on-line 

monitoring  and  recording,  locating  insulation  faults  and 

repairing electrical lines.

 

Power source

 

DC6V, alkaline battery LR6 1.5V×4

 

Testing 

Method

 

Flexible  Coil  CT,  The  output  signal  is  the  differential  of 

current to time. By integrating the output voltage signal, 

the input current can be truly restored.

 

Coil Diameter 

φ

200mm/

φ

300mm(Can customize to other size) 

Range 

AC 0.00A

6000A/0.00A

20.00kA(Can customize) 

Resolution 

AC 10mA 

Содержание MEWOI9000G

Страница 1: ...Leakage Current Monitoring Recorder MEWOI9000G MEWOI9000GB User Manual www mewoi com...

Страница 2: ......

Страница 3: ...7 VI Instrument Operation 8 1 Turning on and off 8 2 Language Selection 8 3 Change Display Modes 8 4 Selecting Power saving Mode 8 5 Setting Time 9 6 Data Inquiry 10 7 Deleting Data 11 8 Leakage curre...

Страница 4: ...not use the instrument to measure a line with a voltage higher than 600V It is forbidden to use the instrument when neither rear cover of the instrument nor the battery cover is in place Never use the...

Страница 5: ...use it because continual use may result in danger In this case isolate the instrument immediately and delivered to an authorized agency for dealing with it The user must follow the safety instruction...

Страница 6: ...oped by our technical department the instrument can display leakage current dynamically display current waveform maximum value minimum value and average value The users can preset the alarm limit The...

Страница 7: ...t DC III Series Model Model Range Coil Diameter Coil Length MEWOI9000G AC 0 00A 20000A 300mm 300G 1000mm MEWOI9000GB AC 0 00A 6000A 200mm 200G 630mm IV Technical Specifications Functions Measuring AC...

Страница 8: ...y field 44mm 27mm The electric field interference Has no hysteresis effect and strong anti interference ability Position error The tested conductor should be at the center of the flexible coil as far...

Страница 9: ...h a new one when the battery voltage drops to 4 6V to 4 8V In this case the measured values are still accurate Rated Power about 5mA at the power saving mode maximum current consumption 20mA Lead Leng...

Страница 10: ...left right keys and MEM control key 4 Instrument body 5 POWER key for turning on and turning off the instrument 6 USB data download interface 7 Flexible coil tap port A 8 Flexible coil tap port B 9 Le...

Страница 11: ...pressing the LEFT and RIGHT arrow keys press the MEM key to confirm the selected language and enter the measurement status 3 Change Display Modes After confirming the selected language and entering th...

Страница 12: ...ing mode At the date time setting mode press the UP or DOWN arrow keys to change values press the LEFT or RIGHT keys to move the cursor press MEM key to Confirm or Cancel the setting After the recordi...

Страница 13: ...ets of recorded values and the right side displays the page number increment It is allowed to rapidly navigate to the desired page number Press the UP or DOWN arrow keys to move the cursor and select...

Страница 14: ...only by the trained and authorized person The operators must keep to the safety rules strictly otherwise electric shock will result in personal injury or damage to the equipment Don not use the instr...

Страница 15: ...oil on the wire to be tested and then closing it a plurality of turns For example the measured current is 0 01A After the flexible coil wraps around the tested conductor for 3 turns the test meter dis...

Страница 16: ...te that clamping 4 wires Clamp the three phase 5 wire together to measure the leakage current of three phase 5 wire note that clamping 5 wires For safety when measuring high voltage and high current a...

Страница 17: ...dication has alarm value setting and alarm indication has historical data reading reviewing saving sorting generating curve printing and other functions The introduction is as follows 1 Homepage After...

Страница 18: ...kage record values are arranged from large to small and if the values are the same they are arranged in chronological order 8 History saving Historical data is saved in pages in TXT text format Batter...

Страница 19: ...16 Packing List Host 1PCS Flexible current clamp 1PCS RS232 Communication line 1PCS Monitoring software CD 1PCS Meter package 1PCS User manual warranty card certificate 1PCS...

Страница 20: ......

Страница 21: ...Your Testing Specialist...

Отзывы: