Brief Introduction 

MEWOI9000G/9000GB  Current/Leakage  Monitoring  Recorder

  is  well 

designed and manufactured for online measurement, monitoring and recording of 

AC  leakage  /  current.  It  is  composed  of  a  tester,  monitoring  software,  current 

clamp and communication cable, etc. This instrument

 

has been widely applied in 

many fields, such as electrical power, telecommunication, meteorology, railway, oil 

fields,  construction,  metering,  research  agencies,  universities,  mines  and 

enterprises. 

 

Both  Chinese  and  English  MMI  is  built  in  the  instrument.  Therefore,  it  is 

suitable for use by engineers and technicians of different counties. The instrument 

has  a  large  LCD  display  with  blue  background  and  a  large storage  space.  4200 

sets  of  data  can  be  stored  in  the  instrument.  In  addition,  the  instrument  can 

automatically store data at an interval, which is adjustable from 1 to 60 min. 

MEWOI  leakage/current  monitor  software  provides  online  and  real-time 

monitoring  and  historical  data  inquiry.  With  the  software  developed  by  our 

technical  department,  the  instrument  can  display  leakage  current  dynamically, 

display  current  waveform,  maximum  value,  minimum  value  and  average  value. 

The users can preset the alarm limit. The instrument will generate an alarm when 

the  measured current  exceeds  the  limit.  In addition,  the users  can  read,  inquire, 

store, analyze, process, sequence historical data and generate and print a fitting 

curve and report.   

The  flexible  current  clamp,  using  the  advanced  Rockwell  coil  (or  Rogowski 

coil)  technology,  is  a  circular  coil  that  is  uniformly  twisted  on  non-ferromagnetic 

materials.  There  is  no  hysteresis  effect,  almost  zero  phase  error,  no  magnetic 

saturation,  high  linearity  and  strong  anti-interference  ability.  The  output  signal  is 

the differential of the current to the time. By integrating the output voltage signal, 

the input current can be reduced and the current range can be measured from mA 

to  20000A.  The  flexible  current  clamp  coil  has  no  bare  metal  conductor, 

non-contact measurement, safe and fast, it is small in size, light in weight, delicate 

in appearance, suitable for a place with narrow environment and dense line. The 

user can customize the length of coil according to the requirement.

Содержание MEWOI9000G

Страница 1: ...Leakage Current Monitoring Recorder MEWOI9000G MEWOI9000GB User Manual www mewoi com...

Страница 2: ......

Страница 3: ...7 VI Instrument Operation 8 1 Turning on and off 8 2 Language Selection 8 3 Change Display Modes 8 4 Selecting Power saving Mode 8 5 Setting Time 9 6 Data Inquiry 10 7 Deleting Data 11 8 Leakage curre...

Страница 4: ...not use the instrument to measure a line with a voltage higher than 600V It is forbidden to use the instrument when neither rear cover of the instrument nor the battery cover is in place Never use the...

Страница 5: ...use it because continual use may result in danger In this case isolate the instrument immediately and delivered to an authorized agency for dealing with it The user must follow the safety instruction...

Страница 6: ...oped by our technical department the instrument can display leakage current dynamically display current waveform maximum value minimum value and average value The users can preset the alarm limit The...

Страница 7: ...t DC III Series Model Model Range Coil Diameter Coil Length MEWOI9000G AC 0 00A 20000A 300mm 300G 1000mm MEWOI9000GB AC 0 00A 6000A 200mm 200G 630mm IV Technical Specifications Functions Measuring AC...

Страница 8: ...y field 44mm 27mm The electric field interference Has no hysteresis effect and strong anti interference ability Position error The tested conductor should be at the center of the flexible coil as far...

Страница 9: ...h a new one when the battery voltage drops to 4 6V to 4 8V In this case the measured values are still accurate Rated Power about 5mA at the power saving mode maximum current consumption 20mA Lead Leng...

Страница 10: ...left right keys and MEM control key 4 Instrument body 5 POWER key for turning on and turning off the instrument 6 USB data download interface 7 Flexible coil tap port A 8 Flexible coil tap port B 9 Le...

Страница 11: ...pressing the LEFT and RIGHT arrow keys press the MEM key to confirm the selected language and enter the measurement status 3 Change Display Modes After confirming the selected language and entering th...

Страница 12: ...ing mode At the date time setting mode press the UP or DOWN arrow keys to change values press the LEFT or RIGHT keys to move the cursor press MEM key to Confirm or Cancel the setting After the recordi...

Страница 13: ...ets of recorded values and the right side displays the page number increment It is allowed to rapidly navigate to the desired page number Press the UP or DOWN arrow keys to move the cursor and select...

Страница 14: ...only by the trained and authorized person The operators must keep to the safety rules strictly otherwise electric shock will result in personal injury or damage to the equipment Don not use the instr...

Страница 15: ...oil on the wire to be tested and then closing it a plurality of turns For example the measured current is 0 01A After the flexible coil wraps around the tested conductor for 3 turns the test meter dis...

Страница 16: ...te that clamping 4 wires Clamp the three phase 5 wire together to measure the leakage current of three phase 5 wire note that clamping 5 wires For safety when measuring high voltage and high current a...

Страница 17: ...dication has alarm value setting and alarm indication has historical data reading reviewing saving sorting generating curve printing and other functions The introduction is as follows 1 Homepage After...

Страница 18: ...kage record values are arranged from large to small and if the values are the same they are arranged in chronological order 8 History saving Historical data is saved in pages in TXT text format Batter...

Страница 19: ...16 Packing List Host 1PCS Flexible current clamp 1PCS RS232 Communication line 1PCS Monitoring software CD 1PCS Meter package 1PCS User manual warranty card certificate 1PCS...

Страница 20: ......

Страница 21: ...Your Testing Specialist...

Отзывы: