MEWOI MEWOI2600 Скачать руководство пользователя страница 6

-3- 

 

I . Brief Introduction 

MEWOI2600

 

Wireless  High  Voltage  Phase  Detector

  is 

designed specially for high voltage phase detection, break through 
the traditional phase detection voltage limitation, can conduct low 
voltage  phase  detection,  Fully  realized  200V~220kV  voltage 
automatic  phase  detection  (such  as  400V,  10kV,  35kV,  66kV, 
110kV, 220kV), there is no need to purchase multiple sets of phase 
detectors  according  to  the  voltage  level,  save  cost,  reduce  the 
carrying,  and  time-saving.  For  the  phase  of  high  voltage  line 
(voltage over 400V), the detector's metal detector can be gradually 
close  to  the  wire.  When  the  electric  field  signal  is  induced,  the 
phase detection can be completed without the direct contact with 
high  voltage  wire!  When  the  bare  wire  voltage  exceeds  35kV,  a 
non-contact phase detect must be used.

MEWOI2600

 also has the 

functions  of  testing  phase,  frequency,  phase  sequence,  checking 
the electricity, and judging transformer groups. 

MEWOI2600  wireless  high  voltage  phase  detector

  is 

composed  of  a  host  machine,  detector,  telescopic  rod,  insulation 
monitoring  software,  USB  communication  line,  linear  wireless 
signal  transmission  distance  of  about  30  meters,  adopts  3.5  inch 
color  LCD  screen,  you  can  display  with  phase,  frequency,  phase 
and phase results; vector instructions, phase indication, clear and 
intuitive,  with  "X;  normal  signal,  Y  signal  is  normal,  in-phase  and 
out of phase, voice prompt function, make the test more easily. 

The monitoring software has the functions of online real-time 

monitoring,  historical  data  query,  vector  diagram  instruction  and 
phase indication. It has the functions of reading, searching, saving 
and printing historical data. 
 

II. Electrical Symbols 

 

 

Extremely Dangerous! The operator must strictly abide 
by  the  safety  rules.  Otherwise,  there  is  electric  injury 
danger, causing personal damage or casualty accident.

 

 

Dangerous!  The  operator  must  strictly  abide  by  the 
safety  rules.  Otherwise,  there  is  electric  injury  danger, 
causing personal damage or casualty accident. 

Содержание MEWOI2600

Страница 1: ...Wireless High Voltage Phase Detector MEWOI2600 User Manual www mewoi com...

Страница 2: ......

Страница 3: ...cture 6 V Operation 7 1 Host Power On Off 7 2 Detector Power On off 7 3 Data Maintenance 8 4 Data Memory 8 5 Data Reference 8 6 Data Deletion 9 7 LCD Screen 9 8 Data Transmission 9 9 Self checking 9 1...

Страница 4: ...oltage of tested circuitry has exceeded 400V it must be used by connecting with an insulation rod As it is very dangerous of high voltage transmission line the operator must get strict training and th...

Страница 5: ...y danger may occur if continue to use it stop using it immediately and seal it up for keeping at once which shall be dealt with by qualified authorization agency The danger symbol on the meter and the...

Страница 6: ...he electricity and judging transformer groups MEWOI2600 wireless high voltage phase detector is composed of a host machine detector telescopic rod insulation monitoring software USB communication line...

Страница 7: ...ector Zinc manganese dry batteries 6F22 9V Phase Detect Modes 1 Contact Phase Detect can contact wire which is below 35KV bare wire or 220KV With insulation Cover 2 Non Contact Phase Detect conduct no...

Страница 8: ...c shut down Turn on the instrument for about 5 minutes Battery Voltage When the battery voltage dropped to 7 2V 0 1V the battery voltage is low symbol display to remind the replacement of the battery...

Страница 9: ...ral technical requirements for portable nuclear power apparatus for use in 1kV 35kV portable power plants DL T971 2005 IEC61481 A2 2004 IEC 61243 1 ed 2 2003 Accessories Host 1set Detector 2 pieces Pr...

Страница 10: ...cording to manual instructions to install the battery 1 Host Power On Off Press POWER button to power on the instrument will displays the LCD screen Press POWER button to power off If LCD display is r...

Страница 11: ...on again to release data lock returning to normal testing mode and HOLD symbol disappears Data Storage Data Reference 4 Data Memory Under normal testing mode press Left Arrow to hold and store the dat...

Страница 12: ...LCD backlight is automatically stored and the stored brightness value is automatically restored when the instrument is turned on 8 Data Upload Connect the computer and the host USB communication line...

Страница 13: ...onal injury or damage to equipment Cannot be used to test more than 220kV voltage line otherwise there is an electric shock causing personal injury or equipment damage The high voltage test must be co...

Страница 14: ...etal hook detector into metal probe Non contact phase detection If the lines are relatively close to each other should test the position of the wire where is far away from the other wires Phase detect...

Страница 15: ...ough Please replace the battery in time 1 When the battery voltage is below 7 2V 0 1V the meter will display symbol the power indicator flashing Indicates that the battery is low Please replace batter...

Страница 16: ...If not please repeat the operation according the step 2 IX Accessories Host 1pcs Detector 2pcs Detector Probe Hook Probe 2pcs each Calibration line 1pc USB Cable 1pc Monitoring software CD 1pc Bag 1se...

Страница 17: ...Your Testing Specialist...