MEWOI MEWOI2600 Скачать руководство пользователя страница 4

-1- 

 

 

Warning 

 
 
Thanks  for  your  purchase  of 

Wireless  High  Voltage  Phase 

Detector

 

MEWOI2600

 of our company. In order to make better use 

of this product, please make sure to:   

——Read  this  manual  in  detail  and  the  operator  must 

totally  understand  this  manual  and  be  in  proficient  in 
operation of this meter before making test on spot.   

——Strictly  comply  with  the  security  rules  and  notice 

items listed on this manual. 

  Before use, make sure the instrument is in good condition and 

without breakage. In any case, the instrument shall be used 
with particular attention to safety, especially in high-voltage 
phase detection   

  Pay attention to the marked text and symbols of instrument 

panel and backboard   

  If the voltage of tested circuitry has exceeded 400V, it must     

be used by connecting with an insulation rod. 

  As it is very dangerous of high voltage transmission line, the   

operator must get strict training and the relevant certification 
on high-pressure operation of the state before using this meter 
and making a field test.   

  Please do not put or store this meter in the place of high     

temperature, with moisture, with frozen dew or with direct 
daylight irradiation for a long time. 

 

 

  It is recommended that the instrument shall conduct an 

insulation strength test at least once a year 

  Please don

’t use it If the detector, insulation rod and other 

parts are damaged. 

  It is strictly forbidden to use this meter to test the wire without 

any insulate protection or convergence generatrix. 

  Please note the battery polarity when replacing battery, and     

remove  the  battery  if  you  expect  not  to  use  this  meter  for  a 

Содержание MEWOI2600

Страница 1: ...Wireless High Voltage Phase Detector MEWOI2600 User Manual www mewoi com...

Страница 2: ......

Страница 3: ...cture 6 V Operation 7 1 Host Power On Off 7 2 Detector Power On off 7 3 Data Maintenance 8 4 Data Memory 8 5 Data Reference 8 6 Data Deletion 9 7 LCD Screen 9 8 Data Transmission 9 9 Self checking 9 1...

Страница 4: ...oltage of tested circuitry has exceeded 400V it must be used by connecting with an insulation rod As it is very dangerous of high voltage transmission line the operator must get strict training and th...

Страница 5: ...y danger may occur if continue to use it stop using it immediately and seal it up for keeping at once which shall be dealt with by qualified authorization agency The danger symbol on the meter and the...

Страница 6: ...he electricity and judging transformer groups MEWOI2600 wireless high voltage phase detector is composed of a host machine detector telescopic rod insulation monitoring software USB communication line...

Страница 7: ...ector Zinc manganese dry batteries 6F22 9V Phase Detect Modes 1 Contact Phase Detect can contact wire which is below 35KV bare wire or 220KV With insulation Cover 2 Non Contact Phase Detect conduct no...

Страница 8: ...c shut down Turn on the instrument for about 5 minutes Battery Voltage When the battery voltage dropped to 7 2V 0 1V the battery voltage is low symbol display to remind the replacement of the battery...

Страница 9: ...ral technical requirements for portable nuclear power apparatus for use in 1kV 35kV portable power plants DL T971 2005 IEC61481 A2 2004 IEC 61243 1 ed 2 2003 Accessories Host 1set Detector 2 pieces Pr...

Страница 10: ...cording to manual instructions to install the battery 1 Host Power On Off Press POWER button to power on the instrument will displays the LCD screen Press POWER button to power off If LCD display is r...

Страница 11: ...on again to release data lock returning to normal testing mode and HOLD symbol disappears Data Storage Data Reference 4 Data Memory Under normal testing mode press Left Arrow to hold and store the dat...

Страница 12: ...LCD backlight is automatically stored and the stored brightness value is automatically restored when the instrument is turned on 8 Data Upload Connect the computer and the host USB communication line...

Страница 13: ...onal injury or damage to equipment Cannot be used to test more than 220kV voltage line otherwise there is an electric shock causing personal injury or equipment damage The high voltage test must be co...

Страница 14: ...etal hook detector into metal probe Non contact phase detection If the lines are relatively close to each other should test the position of the wire where is far away from the other wires Phase detect...

Страница 15: ...ough Please replace the battery in time 1 When the battery voltage is below 7 2V 0 1V the meter will display symbol the power indicator flashing Indicates that the battery is low Please replace batter...

Страница 16: ...If not please repeat the operation according the step 2 IX Accessories Host 1pcs Detector 2pcs Detector Probe Hook Probe 2pcs each Calibration line 1pc USB Cable 1pc Monitoring software CD 1pc Bag 1se...

Страница 17: ...Your Testing Specialist...

Отзывы: