MEWOI MEWOI1310B Скачать руководство пользователя страница 14

 

 

 

10 

7.  Replace Batteries 

 

Warning!  Do  not  test  if the  battery cover  plate  is  not  well  covered,  otherwise  it is 

dangerous.

 

pay attention to the battery polarity, or will damage the meter 

Do not mix new and old batteries for use 

 

7.1.  When  battery  voltage  of  the  receiver  is  lower  than  4.8V,  the  meter  will  continue  to 

display “          ” symbol, indicate that low battery. Please replace batteries in time.   

7.2.  Power  off  and  make  sure  the  meter  is  off  state.  Loosen  two  screws  and  open  the 

battery  cover  plate  to  replace  new  qualified  batteries,  pay  special  attention  on  the  battery 

specification and polarity, and then cover the board well and fasten the two screws.   

7.3. Press POWER key to check whether the meter can    power on normally or not. If not, 

please repeat the operation according the step 2.   

 
 
 

 
 
 
 
 

 

8.  Accessories 

Detector 

1PCS

 

Receiver   

1PCS 

Wireless Antenna 

1PCS 

Stretch Insulation Rod

 

1PCS 

Meter Case 

1PCS 

Manual/ Maintenance Card/ Certificate 

1SET 

 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание MEWOI1310B

Страница 1: ...Wireless High Voltage U Type Current Meter MEWOI1310B User Manual www mewoi com...

Страница 2: ......

Страница 3: ......

Страница 4: ...or Special Symbols 5 5 3 Display Demonstration 6 6 Operation Method 7 6 1 Detector Operation 7 6 1 1 Power On Off 7 6 1 2 General Test 7 6 1 3 Test Area 8 6 1 4 Data Transmission 8 6 2 Receiver Operat...

Страница 5: ...o use this meter to test bare wires or busbars with voltage over 500kV Pay attention to the text labeled on the panel and backplane of the Meter Do not place and store the meter in high temperature an...

Страница 6: ...se Below 600V circuit no need the insulation rod and use the u type current meter to measure directly The meter has data hold and data storage function Insulation rod is equipped with adjustable inter...

Страница 7: ...tage AC current on line monitoring of low voltage AC current and AC current Power Supply DC6V Alkaline Dry Battery 1 5V AAA X4pcs Test Method Non contact U type CT Transmission Method 433MHz wireless...

Страница 8: ...ement range overflow function OL A symbol display No signal Indication When the receiver has not received transmit signal dynamic display no symbol Auto Shut Down About 15 minutes after boo up the met...

Страница 9: ...symbol 5 1 4 Date access symbol 5 1 5 2 digit Storage Data Serial Number 5 1 6 Unit Symbol 5 1 7 Date Locked Symbol 5 1 8 Decimal System Radix Point 5 1 9 4 Digit LCD Digital Display 5 2 Explanation...

Страница 10: ...meter not in test mode or adjust received signal location and distance 5 3 Display Demonstration 5 3 1 The tested current 0 002A 2mA 5 3 2 Locked display Data The data is automatic stored as group 3...

Страница 11: ...ric shock causing personal injury or injury accident Dangerous It is strictly forbidden to use this meter to test bare wires or busbars with voltage over 110kV otherwise there would be danger of elect...

Страница 12: ...ill increase by twice or more and the position error of the semicircle area at point B will increase by 1 6 1 4 Data Transmission The meter has the function of wireless transmitting test data When the...

Страница 13: ...l indication Press HOLD key again to cancel data lock state return to receiving data mode HOLD symbol disappear 6 2 4 Data Storage In the mode of receiving data press the HOLD key to hold the data whi...

Страница 14: ...ace batteries in time 7 2 Power off and make sure the meter is off state Loosen two screws and open the battery cover plate to replace new qualified batteries pay special attention on the battery spec...

Страница 15: ...11...

Страница 16: ...12 Your Testing Specialist...

Отзывы: