53
NDX VALVE CONTROLLER
13.4
Using DTM
This section introduces standard DTM functions and
explains how to perform them efficiently. Note that after
installing DTM, you must update DTM Catalog in the frame
application before you can use the DTM.
13.4.1
DTM settings
Metso DTM setup package installs an additional utility, which
provides global DTM configuration options. It allows chang
ing DTM language and save data folder. The configurator util
ity can be started from Start menu
→
All Programs
→
Metso
Device DTM
→
Metso NDX DTM
→
NDX DTM Configurator.
Fig. 52
13.4.2
Frame application functions
Here is an example of a FDT frame application menu struc
ture, which provides access to different DTM functions:
Fig. 53
The example is showing, where Import/Export functionality
can be found and how to access Offline/Online parame
terization and Diagnosis functionality.
13.4.3
Import/Export
The Export function of DTM allows you to save device con
figurations on your computer or local computer network
for later use or as a backup file. The Import function allows
you to load previously saved configurations into the DTM
for use in device configuration. Exported configurations
are saved in .xml file format.
Location of the Import and Export functions depends on
the FDT frame application used. Usually there is a menu
(or contextmenu with right mouse click), which provides a
set of standard actions, for example “Online Parameterize”.
In this same menu should be a section called “Additional
Functions”. Under the Additional Functions menu are the
Import and Export functions.
13.4.4
Printing
Printable report from a device via a DTM instance is available
through the frame application functions.
13.5
NDX DTM
Metso DTM provides three different user interfaces, each
for very distinct purpose:
1. Parameterize Offline window
2. Parameterize Online window
3. Diagnosis window
These views are available from the FDT frame application
menu structure.
13.5.1
Parameterize Offline
Fig. 54
Following DTM views are available when device is in offline
mode:
Device Information
Status Configuration
All Parameters
Please see the chapter Parameterize Online for detailed
information on each view.
13 DEVICE TYPE MANAGER (DTM)
OPER
ATION
Содержание NELES NDX 511 Series
Страница 80: ...80 NDX VALVE CONTROLLER 15 1 NDX1510 LINEAR APPLICATION ROTARY APPLICATION Fig 98 15 DIMENSION DRAWINGS ...
Страница 82: ...82 NDX VALVE CONTROLLER 15 3 NDX_512_ Tightening torque 15 Nm 48 Fig 100 15 DIMENSION DRAWINGS ...
Страница 84: ...84 NDX VALVE CONTROLLER Fig 103 NDX_511_ Fig 104 NDX_512_ 15 DIMENSION DRAWINGS ...