DRIVING INSTRUCTIONS
24
D100014616-EN
398 0 EN 2021-06-22
DRIVING INSTRUCTIONS
Problem
Reason
Consequence
Corrective actions
Engine start failed
Hydraulic shut-off valve is
closed.
Engine start is prevented. "Opening the hydraulic
Engine start failed
Hydraulic oil temperature
is too high.
Engine start is prevented.
Radio control device is
not working
The battery of radio
control device is empty or
the battery charge level is
low.
Radio control device
cannot be used.
Track drive does not work Manual valve mode is
activated.
The machine cannot be
driven to any direction.
Track drive does not work Process is not stopped.
The machine cannot be
driven to any direction.
Track drive does not work Manual controls are
active.
The machine cannot be
driven to any direction.
Track drive does not work
Drive control device or
radio control device was
connected before starting
the engine.
The machine cannot be
driven to any direction.
Reconnect/Reactivate the
control device.
Engine is not running
properly or it suddenly
stopped.
Fuel tank is empty.
The machine cannot be
driven.
Engine is not running
properly or it suddenly
stopped.
When driving on a
sloping surface or
onto a trailer truck, the
automation system may
stop the machine if the
hydraulic fluid or the
coolant level is too low.
The machine cannot be
driven.
System display shows an
alarm
Engine did not start.
Engine start is prevented. "Handling alarms",
System display shows an
‘A17: Remote stop active’
alarm
Remote stop button is
pressed down.
Engine start is prevented.
System display shows an
emergency stop alarm
One or more emergency
stop buttons are pressed
down.
Engine start is prevented. "Handling the emergency
1.12. CORRECTIVE ACTIONS
1.12.1. MAKING SURE THAT THE MAIN SWITCH IS ON
1. Locate the main switch.
You can find it from the right side of the machine, near the main control center.