![Metronix DIS-2 310/2 FB FS STO Скачать руководство пользователя страница 99](http://html.mh-extra.com/html/metronix/dis-2-310-2-fb-fs-sto/dis-2-310-2-fb-fs-sto_product-manual_1780027099.webp)
Electrical installation
Page 99
Product Manual
“Servo drive DIS-2 310/2 FB FS STO“
Version 4.0
8.3.4
Connection: EtherCAT [X401] and [X402]
The EtherCAT interface at the servo drive DIS-2 310/2 FB FS STO is configured according to
IEC 61076-2-101 as a 4-pole M12 socket, shielded and D-coded at the technology module.
Configuration on the device:
[X401]
M12 flush-type plug, 4-pin type, D-coded
[X402]
M12 flush-type plug, 4-pin type, D-coded
Counterplug:
Assembled M12 Bus cable for example made by Phoenix
Contact, shielded M12, D-coded, 4-pin type cable
pre-fabricated lengths, order number:
Length in metres
Order number
0,3
1523065
0,5
1523078
1,0
1523081
2,0
1521533
Length in metres
Order number
5
1524051
10
1524064
15
1524077
Figure 35:
Position and connection EtherCAT interface
Table 43:
Pin assignment [X401] and [X402]
Pin No. Denomination
Values
Specification
1
TX+
0 ... 2,5 VDC
Transmission Data +
2
RX+
0 ... 2,5 VDC
Receive Data +
3
TX-
0 ... 2,5 VDC
Transmission Data -
4
RX-
0 ... 2,5 VDC