![Metronix DIS-2 310/2 FB FS STO Скачать руководство пользователя страница 93](http://html.mh-extra.com/html/metronix/dis-2-310-2-fb-fs-sto/dis-2-310-2-fb-fs-sto_product-manual_1780027093.webp)
Electrical installation
Page 93
Product Manual
“Servo drive DIS-2 310/2 FB FS STO“
Version 4.0
8.2.7
Connection: Safe Torque Off (STO) [X40] and [X40A]
For further information concerning the safety function please refer to
chapter 6
.
Configuration on the device [X40]:
Molex No. 87832-0614
Counterplug [X40]:
Molex No. 51110-0660 with up to 6 contacts
Molex No. 50394-8051
Configuration on the mounting plate [X40A]:
for example: PhoenixContact M12 socket
(SACC-DSI-FS-5P-PG 9/0,5 SCO 0,25), rear panel
5-pin-type A-coded
Counterplug [X40A]:
for example: M12 plug with xx m cable length:
SAC-5P-MS/xx-PUR SAC
Length in metres
Order number
1,5
1518960
5,0
1518986
10.0
1518999
6
5
4
3
2
1
X40
Example for
[X40A]:
The counterplug
Molex
No. 51110-0660
mentioned above is
attached to the free
cable ends.
Figure 31:
Position and connection STO signals [X40] and [X40A]