![Metronix DIS-2 310/2 FB FS STO Скачать руководство пользователя страница 87](http://html.mh-extra.com/html/metronix/dis-2-310-2-fb-fs-sto/dis-2-310-2-fb-fs-sto_product-manual_1780027087.webp)
Electrical installation
Page 87
Product Manual
“Servo drive DIS-2 310/2 FB FS STO“
Version 4.0
8.2.2
Connection: Motor [X6]
Configuration on the device [X6]:
JST No. B5P-VH-B
Counterplug [X6]:
JST No. VHR-5N with 4 contacts JST No. SVH-41T-
P1.1
Figure 26:
Position and connection motor cable
Table 32:
Pin assignment [X6]
Pin No. Denomination Values
Specification
1
PHASE_W
3 x 0 V...300 V
2 A
eff,nom
6 A
eff,max
0 Hz...300 Hz
Connection of the three motor phases
2
PHASE_V
3
PHASE_U
4
n.c.
Safety clearance between PE and motor phase
5
PE
Protective earth
8.2.3
Connection: Angle encoder [X2]
Configuration on the device [X2]:
Molex No. 87832-1614
Counterplug [X2]:
Molex No. 51110-1651 with up to 16 contacts
Molex No. 50394-8051
2
1
4
3
6
5
8
7
10
9
12 11
14 13
16 15
X2
Figure 27:
Position and connection angle encoder