![Metronix DIS-2 310/2 FB FS STO Скачать руководство пользователя страница 66](http://html.mh-extra.com/html/metronix/dis-2-310-2-fb-fs-sto/dis-2-310-2-fb-fs-sto_product-manual_1780027066.webp)
Functional safety technology
Page 66
Product Manual
“Servo drive DIS-2 310/2 FB FS STO“
Version 4.0
Notes concerning the circuit example
The servo drive with a safety module does not include any crossfault detection.
In the case of a direct wiring of light grids, the crossfault detection will be performed by the light
grid provided that it is suitable for this purpose.
If safety switching devices are used, the contacts REL1 and REL2 can be integrated in the
feedback loop of the safety switching device.
The illustration shows the pin assignment of the STO connector X40 directly on the board and not
the pin assignment of the circular connector in the mounting plate.