Technical data
Page 43
Product Manual
“Servo drive DIS-2 310/2 FB FS STO“
Version 4.0
4.6
STO interface [X40]
Table 20:
Technical data: Control ports [X40] (STO1, STO2):
Parameter
Values
Nominal voltage
24 V (related to GND)
Voltage range
19,2 ... 28,8V
Permissible residual ripple
2 % (related to nominal voltage 24 V)
Input current STO1
0,5 mA (typical; maximum 1 mA)
Input current STO2
25 mA (typical; maximum 30 mA)
Input voltage threshold
Switching on
Switching off
approx. 17 V
approx. 15,5 V
Switch-on time STO1 from Low
to High (t
STO1-ON
)
5 ms (typical; maximum 10 ms)
Switch-on time STO2 from Low
to High (t
STO1-ON
)
10 ms (typical; maximum 15 ms)
Switch-off time STO1 from High
to Low (t
STO1-OFF
)
5 ms (typical; maximum 10 ms)
Switch-off time STO2 from High
to Low (t
STO2-OFF
)
55 ms (typical; maximum 60 ms)
Maximum test impulse length
STO1/2 for OSSD signals
19,2 V
24 V
28,8 V
max. 2,5 ms
max. 4 ms
max. 4 ms
Table 21:
Technical data: Feedback contact [X40] (REL1, REL2):
Parameter
Values
Version
Floating relay contact, normally open
Voltage range contacts
< 30 V (overvoltage-proof up to 60 V DC)
Nominal current
< 200 mA (not short circuit proof)
Voltage drop
< 200 mV
Residual current
(contact opened)
< 1µA
Switching time closing
< 1ms
Switching time opening
< 0,5 ms