![Metronix DIS-2 310/2 FB FS STO Скачать руководство пользователя страница 105](http://html.mh-extra.com/html/metronix/dis-2-310-2-fb-fs-sto/dis-2-310-2-fb-fs-sto_product-manual_1780027105.webp)
Service functions and error messages
Page 105
Product Manual
“Servo drive DIS-2 310/2 FB FS STO“
Version 4.0
10
Service functions and error
messages
10.1
Protection and service functions
10.1.1
Overview
The DIS-2 310/2 FB FS STO servo drive has an extensive sensor system that monitors the controller
unit, power output stage, motor, and the communication with the outside world. Errors that occur will be
stored in the internal error memory. Most errors will cause the controller unit to shut down the servo
drive and power output stage. The servo drive can only be switched on again after the error memory
has been erased by an acknowledgement and after the error has been eliminated or ceased to exist.
Operational safety is ensured by an extensive sensor system and numerous monitoring functions:
Measurement of the motor temperature
Measurement of the power unit temperature
Measurement of the temperature inside the housing
Detection of earth faults (PE)
Detection of connections between two motor phases
Detection of a short circuit of the braking resistor
Detection of undervoltage/overvoltage in the intermediate circuit
Detection of errors concerning the internal voltage supply
Measurement of the average power loss (I²t monitoring) of the servo drive and motor
Detection of errors during the current measurement process
Detection of errors of the rotary encoder
Detection of errors during the motor identification process
Monitoring of the motion sequence
Detection of internal errors
Monitoring of the STO functionality