![Metronix DIS-2 310/2 FB FS STO Скачать руководство пользователя страница 104](http://html.mh-extra.com/html/metronix/dis-2-310-2-fb-fs-sto/dis-2-310-2-fb-fs-sto_product-manual_1780027104.webp)
Start-up
Page 104
Product Manual
“Servo drive DIS-2 310/2 FB FS STO“
Version 4.0
9.6
Checking whether the system is ready for operation
1.
Ensure that the servo drive enabling (DIN9) is inactive (LOW).
2.
Switch the power supply of all of the devices on.
3.
Start the DIS-2 ServoCommander
TM
.
4.
The communication with the servo drive will be started.
5.
Parameterise the servo drive depending on the application.
If the communication with the servo drive could not be started, there is a malfunction. Perform the
following steps:
1.
Switch the power supply off.
2.
Wait for 5 minutes in order to be sure that the intermediate circuit has been discharged.
3.
Check all of the connecting cables.
4.
Check whether the 24 V power supply operates correctly.
5.
Switch the power supply on.