Start-up
Page 102
Product Manual
“Servo drive DIS-2 310/2 FB FS STO“
Version 4.0
9
Start-up
9.1
General connection notes
Since the way the connecting cables are laid is highly important for EMC considerations,
ensure to comply with the information that is given in
section 8.4 Notes concerning the
safe and EMC-compliant installation
DANGER!
Non-compliance with the safety instructions that are stated in
chapter 2 Safety notes for
electrical drives and controllers
may result in damage to property, injuries, electric shock
or, in extreme cases, in death.
9.2
Tools/material
PC with the parameterisation software DIS-2 ServoCommander
TM
Serial interface cable
DIS-2 310/2 FB FS STO control panel or control unit
Power supply cable
Screwdriver or Allen key, depending on the screws with which the DIS-2 310/2 FB FS STO is
fastened on the motor
9.3
Connecting the DIS-2 310/2 FB FS STO servo drive
to the motor
Connect the connector (see the connector set in
section 1.2 Scope of supply
) to the motor cable.
Then, connect it to the corresponding interface [X6] on the DIS-2 310/2 FB FS STO and let it lock
into place.
Connect the connector (see the connector set
) to the encoder cable and, if
included, also to the motor temperature sensor. Then, connect it to the corresponding interface
[X2] on the DIS-2 310/2 FB FS STO and let it lock into place.
Connect the connector (see the connector set
) to the cable of the holding
brake (if necessary). Then, connect it to the corresponding interface [X3] on the DIS-2 310/2 FB
FS STO and let it lock into place.
Screw the braking resistor (see the accessories
) (if necessary) onto the
mounting plate. Connect it to the corresponding interface [X300] on the DIS-2 310/2 FB FS STO
and let it lock into place.
Check all of the plug-in connections.