6 Technical data
6.5
BL 4100-M / BL 4100-D:
Motor connector [X6]
Performance data
Supply voltage 230 VAC [± 10 %], 50 Hz, f
PWM
= 5 kHz, f
el
> 2 Hz,
T
Ambient
= 30°C
Characteristic
BL 4104-D
BL 4104-M
Nominal output power
800 W
700 W
Maximum output power for 2 s
2400 W
2400 W
Nominal output current
4 A
eff
3 A
eff
Max. output current for 2 s
12 A
eff
12 A
eff
Power loss/efficiency
*)
4 % / 96 %
*)
As a guide value for the cooling measures.
Current derating
The BL 4100-M / BL 4100-D series servo drives have a current derating during nominal
operation. The rated current and the duration of the maximum permissible peak current of
the servo drive depend on several factors. These factors are:
l
Output current level: The higher the output current is, the shorter the permissible
time will be.
l
Clock frequency of the power output stage: The higher the clock frequency is, the
shorter the permissible time will be.
The current derating begins as of a PWM frequency of 10 kHz (f
PWM
) and is linear
between the reference values that are stated in the following table:
PWM frequency f
PWM
*)
BL 4104-M / BL 4104-D
I
nominal
I
max
10 kHz
4 A
12 A
16 kHz
3 A
9 A
*)
The PWM frequency is the reciprocal of half of the current controller cycle time t
i
. The
variable cycle times enable particularly high dynamics combined with reduced power
data.
Motor cable requirements
Characteristic
Value
Cable length
l
≤
2 m
See section 5.1
Notes concerning the safe and EMC-
Cable capacity
C‘
≤
160 pF/m
of one phase against shield or between two lines
Mounting Instructions BL 4000-M and BL 4000-D
Page 71 of 95
Содержание 9200-4104-2000
Страница 89: ...9 Appendix BL 4800 M BL 4800 D Mounting Instructions BL 4000 M and BL 4000 D Page 89 of 95 ...
Страница 91: ...9 Appendix Mounting Instructions BL 4000 M and BL 4000 D Page 91 of 95 ...
Страница 93: ...9 Appendix Mounting Instructions BL 4000 M and BL 4000 D Page 93 of 95 ...
Страница 94: ...9 Appendix Mounting Instructions BL 4000 M and BL 4000 D Page 94 of 95 ...