BULLETIN
O-2400
JUNE 1989
METRONIC 5200BF
ELECTROLYTIC RECOVERY SYSTEM
FOR COLOR PHOTO PROCESSING
TABLE OF CONTENTS
Statement of Warranty and Liability.
Introduction
Specifications
Installation
Bill of Materials
Operating Procedures
Trouble Shooting Guide
Silver Stripping Procedures
Silver Flake Refining
Dwg #A-1442 - Diagram, Chemical Interconnection
Swg #A-1445 - Chamber Components
Fig A - 5200 BF
Fig B - Interconnections
Fig C - Float Assembly & Drain Hose
Fig D - Plating Chamber & Connections
Fig E - Pump Locations
Fig F - Front view with cover removed
Fig G - Rear view of E.M.P. Locking Latch
Fig H - E.M.P Assembly
Fig J - E.M.P. Assembly showing timing switches
damage outside the control of SERFILCO are not covered
by this warranty. Under no circumstances shall SERFILCO
be responsible for any damage, loss or liability of any nature
arising out of the installation or use of the materials or
equipment furnished.
No other warranties, expressed or implied, except as
stated above, shall apply. This warranty becomes null and
void if any device or accessories other than those distributed
or officially recommended by SERFILCO is installed, or
attached to this equipment.
INTRODUCTION
The Metronic 5200 BF is an electrolytic recovery system
intended to recover silver from fixer and bleach fix. This is
a closed loop recirculating recovery system that continu-
ously passes the spent fixer and bleach fix solution from the
10 gallon desilvering tank through the plating chamber. The
silver is deposited on a cathode inside the electrolytic
chamber. The unit turns on automatically when the 10 gallon
desilvering tank reaches the 3.5 gallon level.
The unit will run in the recirculating mode until the
maximum amount of silver has been recovered.
At the end of the recirculating cycle, which varies with
silver concentration, the unit will go into a drain mode until
all the chemistry is out of the holding tank and plating
chamber. It will then automatically turn off and wait for the
next batch of chemistry.
1.
2.
3.
Electrolytic Chamber (SPU) (See Fig. B)
This chamber is equipped with one (1) round 5" anode,
one (1) 8" cathode, one(1) circulation pump, and one(1)
discharge pump.
Rectifier (EMP) (See Fig. H)
The rectifier is equipped with digital current readout, level
control, and power switch.
Desilvering Tank (See Fig. F)
The desivlering tank is a 10 gallon holding tank with High/
Low level controls set to start at about 3.5 gallons.
The Metronic 5200 BF consists of:
SAFETY PRECAUTIONS
BEORE STARTING PUMP
Read operating instructions and instructions supplied
with chemicals to be used.
Refer to Chemical Resistance Data Chart for compati-
bility of materials in pump with solutions to be used.
Note temperature and pressure limitations.
Personnel operating pump should always wear suitable
protective clothing: face mask or goggles, apron and
gloves.
All piping must be supported and aligned independently
of the pump.
Always close valves slowly to avoid hydraulic shock.
Ensure that all fittings and connections are properly
tightened.
1.
2.
3.
4.
5.
6.
7.
BEFORE CHANGING APPLICATION OR
PERFORMING MAINTENANCE
Wear protective clothing as described in item 4 above.
Flush pump thoroughly with a neutralizing solution to
prevent possible harm to personnel.
Verify compatibility of materials as stated in item 2
above.
1.
2.
3.
STATEMENT OF WARRANTY AND LIABILITY
SERFILCO warranties its equipment against defects in
material and workmanship for six months from the date of
installation. Any claimed defects must be reported, and the
material or equipment returned, freight prepaid, to our plant
within the warranty period. Our liability is limited to replacing
or repairing, at our option, any material or equipment, at no
cost to the purchaser, Damages or loss during shipment are
not covered by this warranty, but are the responsibility of the
carrier(s). Please report all shipping damage to the carrier(s)
immediately.
All material and /or equipment supplied by vendors other
than SERFILCO, shall carry no warranty except said supplier's
warranty as to materials and workmanship. Transportation
handling damage, wear and tear, and other causes of
1
1
2
2
3
2
4
5
5