BULLETIN
O-2400
JUNE 1989

METRONIC 5200BF

ELECTROLYTIC RECOVERY SYSTEM

FOR COLOR PHOTO PROCESSING

TABLE OF CONTENTS

Statement of Warranty and Liability.
Introduction
Specifications
Installation
Bill of Materials
Operating Procedures
Trouble Shooting Guide
Silver Stripping Procedures
Silver Flake Refining

Dwg #A-1442 - Diagram, Chemical Interconnection
Swg #A-1445 - Chamber Components
Fig A    - 5200 BF
Fig B   - Interconnections
Fig C   - Float Assembly & Drain Hose
Fig D  -  Plating Chamber & Connections
Fig E   -  Pump Locations
Fig F  - Front view with cover removed
Fig G - Rear view of E.M.P. Locking Latch
Fig H   - E.M.P Assembly
Fig J   - E.M.P. Assembly showing timing switches

damage outside  the control of SERFILCO are not covered
by this warranty. Under no circumstances shall SERFILCO
be responsible for any damage, loss or liability of any nature
arising out of the installation or use of the materials or
equipment furnished.

No other warranties, expressed or implied, except as

stated above, shall apply. This warranty becomes null and
void if any device or accessories other than those distributed
or officially recommended by SERFILCO is installed, or
attached to this equipment.

INTRODUCTION

The Metronic 5200 BF is an electrolytic  recovery system

intended to recover silver from fixer and bleach fix. This is
a closed loop recirculating recovery system that continu-
ously passes the spent fixer and bleach fix solution from the
10 gallon desilvering tank through the plating chamber. The
silver is deposited on a cathode inside the electrolytic
chamber. The unit turns on automatically when the 10 gallon
desilvering tank reaches the 3.5 gallon level.

The unit will run in the recirculating mode until the

maximum amount of silver has been recovered.

At the end of  the recirculating cycle, which varies with

silver concentration, the unit will go into a drain mode until
all the chemistry is out of the holding tank and plating
chamber. It will then automatically turn off and wait for the
next batch of chemistry.

1.

2.

3.

Electrolytic Chamber (SPU) (See Fig. B)
This chamber is equipped with one (1) round 5" anode,
one (1) 8" cathode, one(1) circulation pump, and one(1)
discharge pump.
Rectifier (EMP) (See Fig. H)
The rectifier is equipped with digital current readout, level
control, and power switch.
Desilvering Tank (See Fig. F)
The desivlering tank is a 10 gallon holding tank with High/
Low level controls set to start at about 3.5 gallons.

The Metronic 5200 BF consists of:

SAFETY PRECAUTIONS
BEORE STARTING PUMP

 Read operating instructions and instructions supplied
with chemicals to be used.
 Refer to Chemical Resistance Data Chart  for compati-
bility of materials  in pump with solutions to be used.
 Note temperature and pressure limitations.
Personnel operating pump should always wear suitable
protective clothing: face mask or goggles, apron and
gloves.
All piping must be supported and aligned independently
of the pump.
Always close valves slowly to avoid hydraulic shock.
Ensure that all fittings and connections are properly
tightened.

1.

2.

3.
4.

5.

6.
7.

BEFORE CHANGING APPLICATION OR
PERFORMING MAINTENANCE

Wear protective clothing as described in item 4 above.
Flush pump thoroughly with a neutralizing solution to
prevent possible harm to personnel.
Verify compatibility of materials as stated in item 2
above.

1.
2.

3.

STATEMENT OF WARRANTY AND  LIABILITY

SERFILCO warranties its equipment against defects in

material and workmanship for six months from the date of
installation. Any claimed defects must be reported, and the
material or equipment  returned, freight prepaid, to our plant
within the warranty period. Our liability is limited to replacing
or repairing, at our option, any material or equipment, at no
cost  to the purchaser, Damages or loss during shipment are
not covered by this warranty, but are the responsibility of the
carrier(s). Please report all shipping damage to the carrier(s)
immediately.

All material and /or equipment supplied by vendors other

than SERFILCO, shall carry no warranty except said supplier's
warranty as to materials and workmanship. Transportation
handling damage, wear and tear, and other causes of

1
1
2
2
3
2
4
5
5

Содержание 5200BF

Страница 1: ...lly turn off and wait for the next batch of chemistry 1 2 3 Electrolytic Chamber SPU See Fig B This chamber is equipped with one 1 round 5 anode one 1 8 cathode one 1 circulationpump andone 1 dischargepump Rectifier EMP See Fig H Therectifierisequippedwithdigitalcurrentreadout level control and power switch Desilvering Tank See Fig F Thedesivleringtankisa10gallonholdingtankwithHigh Low level contr...

Страница 2: ...eck system for leaks by filling tank with water until system turns on The system will run for approximately 7 minutes then go to drain mode SPECIFICATIONS B EXISTING LABS Connect hoses as indicated on the previous page 1 1 2 3 4 5 6 7 OPERATINGPROCEDURES After completion of installation turn on power The IN hose to the desilvering tank will only allow fix and bleach fix into the tank Whenchangingc...

Страница 3: ...Tie cable 7 1 4 Tie cable 3 3 4 Transformer24 12 Rectifier bridge 25A Capacitor 1900 UF 25V Terminal block 2 pos Cabinet EMP Clamp capacitor Fan cooling Washer 6 lock SS Washer 8 lock SS Washer 6 flat SS Washer 8 flat SS Nut 6 32 SS Nut 8 32 SS Screw 6 32 x 5 8 P H SS Screw 6 32 x 1 2 P H SS Screw 6 32 x 3 8 SS Heatsink 4 Spacer Hex 1 1 4 Cord Power 3 cond 6 Cable 5 cond SPU Assy PCB w harness Ass...

Страница 4: ...oper to drain and clean out the desilvering tank and plating chamber with water 1 Check if fitting is loose If so tighten 2 If fitting is too tight loosen slightly so as not to distort gasket If leak persists disconnect fitting and check gasket for damage 1 Fittings either too tight or not tight enough 2 Flashing around fitting hole 1 Defective EMP 1 Desilvering time too short 2 No amps on digital...

Страница 5: ...ht Occasionally check the cathode and anode nuts for leakage Replace O rings and or spacers if required 10 11 12 SILVER FLAKE REFINING There are numerous silver flake buyers and refiners in your area In the event that you would like a listing of available refiners call our service department and an updated listing will be make available to you Occasionally check the cathode and anode nuts for leak...

Отзывы: