17
I
NSTALLATION
S
ECONDARY
M
ETROLOGIC
S
CANNER
,
C
ABLE
I
NSTALLATION
The following steps describe how to properly install the cables between a secondary
Metrologic
scanner and the Stratos
E
.
The Stratos
E
and the secondary scanner
must
then be configured to communicate properly. Cable installation alone
does not
guarantee that the Stratos
E
will communicate properly with the host system and secondary scanner.
Contact a Metrologic customer service representative
before
connecting another manufacturer’s scanner to the
StratosS as a secondary scanner.
Configuration bar codes are located in the MS2
xxx
Stratos Series Configuration Addendum (
MLPN
00-02034
x
) under
Scanner Configuration Bar Codes:
Auxiliary Port, Quick Start for a Secondary Metrologic Scanner
.
1. Refer to pages 13 - 16 for the type of interface
(RS232, IBM 46xx, etc.)
required for your application. Follow the cable
installation steps under the appropriate interface before continuing. Once the communication and power cables have
been installed follow step 2 below for the secondary scanner installation.
2. Connect
the
straight
10-pin RJ45
end of the
RS232 PowerLink AUX cable (
MLPN
57-57099
x
-3) to the RS232 socket of the
secondary
scanner (
see figure below)
.
3. Connect
the
angled
10-pin RJ45 end of the RS232 AUX cable (
MLPN
57-57099
x
-3) to 10-pin socket labeled
Aux RS232
In,
on the bottom of the Stratos
E.
Important: The StratosE series’ aux port requires the signals; transmit, receive, RTS & CTS from the secondary scanner.
Stratos
E
’ auxiliary port will support 5VDC devices with a 150mA maximum current. If the auxiliary device exceeds this
specification an external power supply will be required to power the auxiliary device.
The following Metrologic scanners can receive power from Stratos
E
: the MS9520, MS9540, and the MS5145.
4.
This step is required for secondary devices that require >5VDC and/or 150mA current to operate.
Skip to step 5 if the secondary device requires
≤
5VDC.
Plug the power supply into the
secondary
scanner’s PowerLink cable (
MLPN
57-57099
x
-3) and connect AC power to the
secondary scanner.
Check the AC input requirements of the power supply to make sure the voltage matches the AC outlet. The outlet
should be located near the equipment and be easily accessible.
5. Configure the Stratos
E
and the secondary scanner. The auxiliary input port’s data format must match the main output
format of the secondary scanner.
Refer to the MS2
xxx
Stratos Series Configuration Addendum (
MLPN
00-02034
x
) under
Scanner Configuration
Bar Codes:
Auxiliary Port, Quick Start for a Secondary Metrologic Scanner
.
Figure 22. AUX Cable Installation Schematic
See power source caution statement on page 8 of this manual.
Содержание StratosE MS2122
Страница 1: ...METROLOGIC INSTRUMENTS INC MS2122 StratosE Installation and User s Guide...
Страница 34: ...30 MAINTENANCE VERTICAL SCAN WINDOW REPLACEMENT Figure 38 Vertical Scan Window Replacement...
Страница 51: ...47 PATENTS Patent Information For patent information please refer to www honeywellaidc com patents...
Страница 52: ...48...
Страница 55: ......
Страница 56: ...March 2008 0 0 0 2 0 2 8 C...