background image

 

 

1

I

NTRODUCTION

  

 
The Quantum

T

 is a hands-free, omnidirectional bar code scanner with optional 

single-line scanning capabilities.   It utilizes the powerful Metrologic Quantum

E

 

scan engine to provide an outstanding scan performance on all standard 1D 
barcode symbologies, including RSS.  This fully enclosed scanner includes large 
easily visible LEDs and a

 

rugged

 

protective boot with an adjustable stand.  The 

Quantum

T

 can be mounted to a countertop, wall or be left free standing for 

handheld scanning. 
 
 
Key Product Features 

 

 

Fully Automatic Scanning Operation 

 

Single-Line Mode for Menu Reading 

 

Custom Configurable Scan Pattern 

 

User-Replaceable Single Cable Interface to Host (PowerLink Compatible) 

 

Decoding of All Standard 1D, RSS-14, RSS Limited and Expanded RSS 
Bar Codes 

 

7 Beeper Tones 

 

Configurable Depth of Field 

 

Flash - Upgradeable Firmware 

 

OPOS and JPOS System Compatible 

 CodeGate

®

 

 Sunrise 

2005 

Compliant 

 
 

Q

UANTUM

T

 

I

NTERFACE

 

MS3580-9 

OCIA and RS232 Transmit/Receive 

MS3580-11 

IBM 46xx and Full RS232 

MS3580-38 

RS232 Low Speed USB,  
Keyboard Emulation Mode or Serial Emulation Mode* 

MS3580-40 

Full Speed USB 

MS3580-41 

RS232/Light Pen Emulation 

MS3580-47 

Keyboard Wedge, Stand-Alone Keyboard and 
RS232 Transmit/Receive 

MS3580-104 

RS232 TTL, Laser Emulation 

 

*  Configurable for Keyboard Emulation Mode or Serial Emulation Mode.

   

Default setting is Keyboard Emulation Mode. 

 

Содержание QuantumT MS3580

Страница 1: ...METROLOGIC INSTRUMENTS INC MS3580 QuantumT Installation and User s Guide...

Страница 2: ...reproduced transmitted or stored in any form or by any means without prior written consent except by reviewer who may quote brief passages in a review or provided for in the Copyright Act of 1976 Prod...

Страница 3: ...ation 8 IBM 46xx or OCIA 9 Keyboard Wedge 10 Stand Alone Keyboard Wedge 11 Full Speed or Low Speed USB Integrated 12 Scanner Operation Configurable Primary and Secondary Scan Pattern Modes 13 Configur...

Страница 4: ...Default Settings Communication Parameters 34 Upgrading the Flash ROM Firmware 39 Scanner and Cable Terminations 40 Scanner Pinout Connections 40 Cable Connector Configurations Host End 42 Laser and P...

Страница 5: ...Reading Custom Configurable Scan Pattern User Replaceable Single Cable Interface to Host PowerLink Compatible Decoding of All Standard 1D RSS 14 RSS Limited and Expanded RSS Bar Codes 7 Beeper Tones...

Страница 6: ...Canada 45 45591 220V 240V Continental European 45 45592 220V 240V United Kingdom 46 46803 220V 240V Australia 46 46983 220V 240V China 54 54000x 3 RS232 PowerLink Cable with Built in Power Jack 2 1 m...

Страница 7: ...B Full Speed Cable Locking Plus Power Type A 5 m 17 ft straight cord short strain relief This cable is for use with full speed USB 40 interface only 54 54235x N 3 USB Low Speed Communication Cable Typ...

Страница 8: ...t 4 Speaker 5 Blue and White LED Indicators 6 Button 7 Protective Boot and Stand Connection Never remove the protective boot from the MS3580 Removing the protective boot will expose electrical compone...

Страница 9: ...tallic pin into the small pin hole 4 You will hear a faint click when the cable lock is released Pull gently on the strain relief of the PowerLink cable to remove it from the scanner Figure 3 Maintena...

Страница 10: ...on Qty Item Description Qty 1 MS3580 QuantumT 1 6 Flexible Shaft 1 2 Pivot Cylinder 1 7 Base Plate Cover 1 3 Bearing Plate 1 8 8 x 1 00 Wood Screw 4 4 Pole Mount Adapter 1 9 Base Plate 1 5 Flexible Sh...

Страница 11: ...7 INTRODUCTION Mounting Specifications and Stand Assembly Optional Flex Stand Figure 6 Mounting Hole Detail for the Flex Stand Base Plate Optional Figure 7 Assembling the Optional Flex Stand...

Страница 12: ...rt of the PC does not guarantee that scanned information will appear at the PC A software driver and correct configuration setting are also required for proper communication to occur The MS3580 104 le...

Страница 13: ...canner into the serial port of the PC does not guarantee that scanned information will appear at the PC A software driver and correct configuration setting are also required for proper communication t...

Страница 14: ...urn on the host device When the scanner first receives power the blue LED will turn on the scanner will simultaneously emit a beep and flash the white LED Powering the MS3580 directly from the host de...

Страница 15: ...will turn on the scanner will simultaneously emit a beep and flash the white LED Powering the MS3580 directly from the host device can sometimes cause interference with the operation of the scanner o...

Страница 16: ...580 38 for USB Serial Emulation Mode please refer to Section P Low Speed USB in the MetroSelect Configuration Guide MLPN 00 02407 Plugging the scanner into the USB port of the PC does not guarantee th...

Страница 17: ...t Each pattern mode can be configured to use one of three scan patterns listed below Please refer to the MetroSelect Configuration Guide for information on changing the default scan pattern settings a...

Страница 18: ...set to single line menu reading with a 5 second button click timeout configured 1 The primary scan pattern is active when the scanner starts 2 To activate the secondary scan pattern press and release...

Страница 19: ...tern has been set to single line menu reading with a 5 second button click timeout configured 1 The primary scan pattern is active when the scanner starts 2 To activate the secondary scan pattern pres...

Страница 20: ...ing and the secondary pattern has been set to single line menu reading with a 5 second button click timeout configured 1 The primary scan pattern is active when the scanner starts 2 To activate the se...

Страница 21: ...igurable Button Functions 5 To scan and transmit additional bar codes repeat steps 2 through 4 6 The primary scan pattern will automatically reactivate after the button is released and no bar code is...

Страница 22: ...5 second button click timeout configured 1 The primary scan pattern is active when the scanner starts 2 To activate the secondary scan pattern press and hold the button 3 To scan and transmit the bar...

Страница 23: ...e light does not flash then the bar code has not been successfully read Razzberry Tone This is a failure indicator Refer to Failure Mode Indicators on page 21 Three Beeps during operation When placing...

Страница 24: ...he scanner successfully reads a bar code the white LED will flash and the scanner will beep once If the white LED does not flash or the scanner does not beep once then the bar code has not been succes...

Страница 25: ...experienced a motor failure Return the unit to an authorized service center for repair Continuous Razzberry Tone with Both LEDs Off If upon power up the scanner emits a continuous razzberry tone then...

Страница 26: ...h of Field Specifications Normal Scan Zone Specifications are based on a 0 33 mm 13 mil bar code Figure 14 MS3580 Normal Depth of Field All specifications are subject to change without notice MS3580 s...

Страница 27: ...of Field Specifications Reduced Scan Zone Specifications are based on a 0 33 mm 13 mil bar code Figure 15 MS3580 Reduced Depth of Field All specifications are subject to change without notice MS3580...

Страница 28: ...Bar Code Element Width Normal Scan Zone MINIMUM BAR CODE ELEMENT WIDTH A B C D E F mm 13 15 19 25 33 66 mils 5 2 5 7 7 5 10 13 26 Figure 16 Normal Scan Zone by Bar Code Element Width All specification...

Страница 29: ...ar Code Element Width Reduced Scan Zone MINIMUM BAR CODE ELEMENT WIDTH A B C D E F mm 13 15 19 25 33 66 mils 5 2 5 7 7 5 10 13 26 Figure 17 Reduced Scan Zone by Bar Code Element Width All specificatio...

Страница 30: ...will cause the scanner to exit power save mode The laser will automatically turn back on preparing the scanner for bar code recognition decoding and transmission Normal Figure 18 Normal IR Activation...

Страница 31: ...are multiple scans upon presentation of code The same symbol timeout is set too short Adjust the same symbol timeout for a longer time increment The beeper is disabled Enable the beeper The unit powe...

Страница 32: ...atches the format required by the host Make sure that the scanner is connected to the proper host port The print quality of the bar code is suspect The aspect ratio of the bar code is out of tolerance...

Страница 33: ...VLD failure Contact a Metrologic service representative During power up the unit razzes twice and both LEDs flash There is a scanner motor failure Contact a Metrologic service representative RS232 Onl...

Страница 34: ...onfigured for the appropriate mode Make sure that the proper PC type ie AT PS2 or XT is selected Verify correct country code and data formatting are selected The unit scans but the data is not correct...

Страница 35: ...Lines 4 Motor Speed 5000 RPM Min Bar Width 0 127 mm 5 0 mil Decode Capability All standard 1 D bar codes including RSS 14 RSS Expanded and RSS 14 Limited System Interfaces RS232 Keyboard Wedge Stand...

Страница 36: ...cal at 5VDC DC Transformers Class II 5 2VDC 650 mA Laser Class 1 IEC 60825 1 1993 A1 1997 A2 2001 EN 60825 1 1994 A11 1996 A2 2001 EMC FCC ICES 003 EN 55022 Class A Environmental Operating Temperature...

Страница 37: ...ge Interface is designed to be used for keyboard emulation only Many RS232 programmable functions e g formatting available in other Metrologic scanners are also available as keyboard wedge functions T...

Страница 38: ...es not support every parameter If the interface supports a parameter listed in the charts on the following pages a check mark will appear PARAMETER DEFAULT OCIA USB RS232 OR RS232 TTL LIGHT PEN IBM 46...

Страница 39: ...High as Scanned Spaces High as Scanned DTS SIEMENS DTS NIXDORF NCR F NCR S Poll Light Pen Source Beeper Tone Normal Beep Transmit Sequence Before Transmit Communication Timeout None Razzberry Tone on...

Страница 40: ...ransmit Lead Zero on UPC E Convert EAN 8 to EAN 13 Transmit UPC A Number System Transmit UPC A Manufacturer ID Transmit UPC A Item ID Transmit Codabar Start Stop Characters CLSI Editing Enable Transmi...

Страница 41: ...TX Prefix ETX Suffix Carriage Return Line Feed disabled by default in KBW Tab Prefix Tab Suffix DE Disable Command FL Laser Enable Command DTR Handshaking Support RTS CTS Handshaking Character RTS CTS...

Страница 42: ...Programmable in 100msec steps MAX 800 msec Coupon Code 128 as code 39 as code 39 Programmable Code Lengths 7 avail Programmable Prefix Characters 10 avail Programmable Suffix Characters 10 avail Pref...

Страница 43: ...tegrated full speed USB 40 and RS232 TTL Laser Emulation 104 units can be upgraded To upgrade all units a power supply and a PowerLink cable MLPN 54 54014 are required RS232 units can be upgraded usin...

Страница 44: ...round 2 RS232 Transmit Output 2 RS232 Transmit Output 3 RS232 Receive Input 3 RS232 Receive Input 4 PC Data 4 RTS Output 5 PC Clock 5 CTS Input 6 KB Clock 6 DTR Input LTPN Source 7 PC 5V 7 Reserved 8...

Страница 45: ...6 DTR Input 6 Clock In 7 IBM B Transmit 7 Clock Out 8 IBM A Receive 8 Clock in Return Clock out Rtrn 9 5VDC 9 5VDC 10 Shield Ground 10 Shield Ground MS3580 104 RS232 TTL Laser Emulation Pin Function...

Страница 46: ...nd 6 Light Pen Data 7 CTS Input 8 RTS Output 9 5VDC USB Power Communication Cable MLPN 54 54213x N 3 54 54214x N 3 or 54 54235x N 3 Pin Function 1 PC 5V V_USB 2 D 3 D 4 Ground Shield Shield Stand Alon...

Страница 47: ...cable with a 5 pin DIN male connector on one end and a 6 pin mini DIN female connector on the other According to the termination required connect the appropriate end of the adapter cable to the Power...

Страница 48: ...me le scanner ou le laser Ne regardez jamais directement le rayon laser m me si vous croyez que le scanner est inactif N ouvrez jamais le scanner pour regarder dans l appareil Ce faisant vous vous ex...

Страница 49: ...ce may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Notice This Class A digital apparatus complies w...

Страница 50: ...nor any damage due to use or misuse produced from integration of the Product into any mechanical electrical or computer system The warranty is void if the case of Product is opened by anyone other th...

Страница 51: ...ht or sublicense is granted either expressly or by implication estoppel or otherwise under any METROLOGIC or third party intellectual property rights whether or not such third party rights are license...

Страница 52: ...ult Settings 13 14 33 34 38 Depth of Field Normal 22 24 31 38 Reduced 23 24 25 31 38 F Failure Modes 21 FCC 45 Firmware 39 Flash ROM 1 39 H Host 27 30 I IBM 9 34 38 Indicator Audible 4 13 19 21 27 30...

Страница 53: ...RMA 46 ROM 29 RS232 8 29 30 34 38 RS232 TTL 8 33 S Scan Lines 31 Scan Pattern 1 31 Horizontal Raster 13 Omnidirectional 13 18 Primary 13 18 Secondary 13 18 Single Line 13 18 Scan Speed 31 SELV 8 12 Si...

Страница 54: ...48 63 78 78 Email info sg metrologic com Fax 33 0 1 48 63 24 94 Email info fr metrologic com China MTLG Auto ID Instruments Shanghai Co Ltd Spain Madrid Tel 86 2158692780 Fax 86 21 58692782 Metrologi...

Страница 55: ......

Страница 56: ...June 2005 Printed in the USA 0 0 0 5 0 9 0 B...

Отзывы: