background image

 

 

16 

P

ROGRAMMING 

M

ODES

 

 

 
4.  During programming, the motor and laser turn off.  YOU CANNOT SCAN A 

BAR CODE WHILE IN SERIAL PROGRAM MODE. 
 

5.  There is a 20 second window between commands.  If a 20 second timeout 

occurs, the scanner will send a [nak] and you must start over. 

 
6.  To enter serial program mode, send the following command 

[stx]999999[etx]. 

 
7.  To exit serial program mode, send the following command [stx]999999[etx], 

the scanner will respond with an [ack] followed by 3 beeps. 

 
8.  This mode uses the current Baud Rate, Parity, Stop Bits and Data Bits 

settings that are configured in the scanner.  The default settings of the 
scanner are 9600, Space, 2, 7 respectively.  If a command is sent to the 
scanner to change any of these settings, the change will NOT take effect 
until after serial program mode is exited. 

 

EXAMPLE #2

:

  

  
The following example will set the scanner to the factory default settings, 
Disable Scanning of Code 128 bar codes, change the beeper tone, and add 
a “G” as a programmable prefix. 

 

  

HOST 

 

SCANNER 

 FEATURE COMMAND ASCII 

REPRESENTATION 

       RESPONSE 

 

Enter Program Mode [stx]999999[etx] 

02h 39h 39h 39h 39h 39h 39h 03h  [ack] or 06h 

 

Load Defaults 

[stx]999998[etx] 

02h 39h 39h 39h 39h 39h 38h 03h  [ack] or 06h 

 

Disable Code 128 

[stx]100113[etx] 

02h 31h 30h 30h 31h 31h 33h 03h  [ack] or 06h 

 

Alternate Tone 1 

[stx]318565[etx] 

02h 33h 31h 38h 35h 36h 35h 03h  [ack] or 06h 

 

Prog. Prefix #1 

[stx]903500[etx] 

02h 39h 30h 33h 35h 30h 30h 03h  [ack] or 06h 

 

Code Byte 0 

[stx]0[etx] 

02h 30h 03h 

[ack] or 06h 

 

Code Byte 7 

[stx]7[etx] 

02h 37h 03h 

[ack] or 06h 

 

Code Byte 1 

[stx]1[etx] 

02h 31h 03h 

[ack] or 06h 

 

Exit Program Mode  [stx]999999[etx] 

02h 39h 39h 39h 39h 39h 39h 03h  [ack] or 06h  

 

The scanner will beep three times! 

 

The commands sent to the scanner do not include the small superscripted 
‘3’ that you see in front of each bar code string in the MetroSelect manual.  
THE ‘3’ SHOULD NOT BE SENT.   IT IS A CODE TYPE DESIGNATION 
ONLY! 

 

As you will note for commands requiring additional bar codes to be scanned 
(such as prefixes, suffixes, timeouts, etc.), simply send the code bytes in the 
same order that you would normally scan the bar codes. 

Содержание Eclipse MS5145-00

Страница 1: ......

Страница 2: ......

Страница 3: ...1 48 63 24 94 Email info fr metrologic com CHINA SUZHOU Metro Technologies Co Ltd SPAIN MADRID Tel 86 512 62572511 Fax 86 512 62571517 Metrologic Eria Ib rica SL Email info cn metrologic com Tel 34 91...

Страница 4: ...odes of Operation 11 Audible Indicators 12 Visual Indicators 13 Failure Modes 14 Programming Modes 15 Upgrading the Flash ROM Firmware 18 Scan Area 19 Labels 20 Applications and Protocols 21 Troublesh...

Страница 5: ...dth of the scan line grows as the scanner moves further away from bar codes In addition the laser beam pulses making lining up bar codes easy and when the scanner senses a bar code CodeSense Mode the...

Страница 6: ...States 00 06156 220V 240V Continental European 00 06156 220V 240V United Kingdom 00 06148 220V 240V China 55 55000A 3 PowerLink Cable with built in power jack 2 1m 7 straight cord long strain relief b...

Страница 7: ...with Full Speed USB scanners only MVC Metrologic Voltage Converter Cable 12VDC to 5 2VDC or 12VDC to 5 2VDC Contact a Metrologic customer service representative for additional information on the MVC c...

Страница 8: ...s the CodeGate button to transmit the data The scanner will beep once and flash the red LED if the bar code was successfully decoded and transmitted default mode only All Eclipse s are shipped configu...

Страница 9: ...s are shipped configured with a set of factory defaults Please refer to the MetroSelect Single Line Configuration Guide or MetroSet2 s help files for instructions on changing the scanner s configurat...

Страница 10: ...s keyboard port If necessary use the supplied adapter cable 5 pin male DIN to 6 pin female mini DIN adapter 7 Power up the PC Powering the MS5145 47 directly from the computer can sometimes cause int...

Страница 11: ...able to the keyboard port on the host system 6 Turn on the host system Powering the MS5145 48 directly from the computer can sometimes cause interference with the operation of the scanner or the compu...

Страница 12: ...perly to the host system All Eclipse s are shipped already configured with a set of factory defaults Please refer to the MetroSelect Configuration Guide or MetroSet2 s help files for instructions on c...

Страница 13: ...in hole on the top of the unit near the bottom of the Eclipse logo 2 Bend an ordinary paperclip into the shape shown above 3 Insert the paperclip or other small metallic pin into the small pin hole 4...

Страница 14: ...ulse and scanning operation and it blinks during power save mode On a successful read of a bar code the red LED will flash and the scanner will beep once The LEDs are also used as diagnostic indicator...

Страница 15: ...t Configuration Guide for instructions on enabling the Manual Activation Mode Figure 10a Figure 10b TWO MODES OF OPERATION CodeGate Out of Stand CodeGate activates when removed from the stand Bar code...

Страница 16: ...rammed to do so If the scanner does not beep once and the red light does not flash then the bar code has not been successfully read Three Beeps during operation When entering the program mode the red...

Страница 17: ...d the scanner will wake up and return to normal pulse mode Steady Green and Single Red Flash When the scanner successfully reads a bar code the red LED will flash and the scanner will beep If the red...

Страница 18: ...ith all LEDs off If upon power up the scanner emits a continuous razzberry tone then the scanner has an experienced an electronic failure Return the unit for repair to a Metrologic Authorized Service...

Страница 19: ...ty to send a series of commands using the serial port of the host system The commands are equivalent to the numerical values of the bar codes located in the MetroSelect Single Line Configuration Guide...

Страница 20: ...tone and add a G as a programmable prefix HOST SCANNER FEATURE COMMAND ASCII REPRESENTATION RESPONSE Enter Program Mode stx 999999 etx 02h 39h 39h 39h 39h 39h 39h 03h ack or 06h Load Defaults stx 9999...

Страница 21: ...tx 999998 etx 02h 39h 39h 39h 39h 39h 39h 03h ack or 06h 19200 Baud Rate stx 415870 etx 02h 34h 31h 35h 38h 37h 30h 03h ack or 06h Exit Program Mode stx 999999 etx 02h 39h 39h 39h 39h 39h 39h 03h ack...

Страница 22: ...54000 3 cable will work The upgrades and custom software versions will be supplied by Metrologic in files called Motorola S record files These files contain all the information needed to upgrade the...

Страница 23: ...19 SCAN AREA Minimum Bar Code Element Width A B C D E F mm 10 12 17 26 33 66 mils 4 1 4 8 6 8 10 4 13 26...

Страница 24: ...LABELS Each scanner has one label on the underside of the unit This label has the model number date of manufacture serial number laser and caution information The following is an example of this labe...

Страница 25: ...for keyboard emulation only Many RS232 programmable functions available in other Metrologic scanners are also available as keyboard wedge functions The following are the most important selectable opti...

Страница 26: ...p the unit beeps 3 times There is a non volatile RAM failure At power up there is a continuous razz tone There is a RAM or ROM failure At power up there is a razz tone and the green LED flashes There...

Страница 27: ...t s data format does not match the host system s requirements Verify that the unit s data format matches that required by the host Make sure that the unit is connected to the proper host port The prin...

Страница 28: ...s may not be supported by that country s key look up table Try operating the scanner in Alt mode The com port at the host is not working or not configured properly Check to make sure that the baud rat...

Страница 29: ...tware and the scanner configuration match If the application does not support RS232 scanners a software wedge program that will take RS232 data and place it into a keyboard buffer may be needed This p...

Страница 30: ...m Interfaces RS232 Keyboard Wedge USB Light Pen Emulation IBM 468X 469X OCIA Stand Alone Keyboard Print Contrast 35 minimum reflectance difference Number Characters Read Up to 80 data characters Maxim...

Страница 31: ...ccordance with IEC 60825 1 1993 A1 1997 A2 2001 Class 1 EMC Class B FCC Part 15 ICES 003 European Union Directive 89 336 EEC ENVIRONMENTAL Operating Temperature 0 C to 40 C 32 F to 104 F Storage Tempe...

Страница 32: ...e default setting is off or disabled Every interface does not support every parameter A check mark will appear in the interface column if it supports the parameter listed Parameter Default OCIA RS232...

Страница 33: ...bol Length Lock None Bars High as Code 39 Spaces High as Code 39 Bars High as Scanned Spaces High as Scanned DTS SIEMENS DTS NIXDORF NCR F NCR S Poll light pen source Beeper tone Normal Beep transmit...

Страница 34: ...in 1 msec steps max 255 msecs 1 msecs 10 msecs in KBW Number of scan buffers maximum 4 Transmit UPC A check digit Transmit UPC E check digit Expand UPC E Convert UPC A to EAN 13 Transmit lead zero on...

Страница 35: ...fault in KBW Tab Prefix Tab Suffix DE Disable Command FL Laser Enable Command DTR Handshaking support RTS CTS Handshaking Character Message RTS CTS XON XOFF Handshaking ACK NAK Two Digit Supplements a...

Страница 36: ...de Lengths 7 avail Code Selects with programmable Code Length Locks 3 avail Programmable Prefix characters 10 avail Suffix characters 10 avail Prefixes for Individual Code types Editing Inter Scan Cod...

Страница 37: ...ular jack The serial label indicates the interface enabled when the scanner is shipped from the factory 10 Shield Ground MS5145 11 IBM 468X 469X Pin Function 1 Ground 2 RS232 Transmit Output 3 RS232 R...

Страница 38: ...5VDC 10 Shield Ground MS5145 00 Laser Emulation Pin Function 1 Ground 2 RS232 Transmit Output 3 RS232 Receive Input 4 Flip Sense Start of Scan Output 5 Proximity Detect Trigger Emulation Output 6 Scan...

Страница 39: ...nd 6 Light Pen Data DSR Out for 14 interfaces 7 CTS Input 8 RTS Output 9 5VDC Stand Alone Keyboard PowerLink Cable 55 55020A 3 Pin Function 1 PC Data 2 NC 3 Power Ground 4 5VDC PC Power to KB 5 PC Clo...

Страница 40: ...a 6 pin mini DIN female connector on the other According to the termination required connect the appropriate end of the adapter cable to the PowerLink cable leaving the necessary termination exposed f...

Страница 41: ...lation or accident nor any damage due to use or misuse produced from integration of the Product into any mechanical electrical or computer system The warranty is void if the case of Product is opened...

Страница 42: ...harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the follo...

Страница 43: ...ui m me le scanner ou le laser Ne regardez jamais directement le rayon laser m me si vous croyez que le scanner est inactif N ouvrez jamais le scanner pour regarder dans l appareil Ce faisant vous vou...

Страница 44: ...or by implication estoppel or otherwise under any METROLOGIC or third party intellectual property rights whether or not such third party rights are licensed to METROLOGIC including any third party pat...

Страница 45: ...stomer service 37 Customer Service 2 3 D Default 4 5 8 16 17 21 28 32 Disclaimer 37 F Failure indicator s 12 14 Failure Indicator s 22 23 Failure modes 14 G Green LED 4 13 22 23 H Host 1 2 8 13 15 17...

Страница 46: ...12 13 14 29 Red LED 4 12 13 18 22 23 Repair 14 RS232 1 2 5 21 24 25 S Service 3 14 37 Stand 2 3 T Termination 6 Terminations 33 34 35 36 Tones 12 Troubleshooting 22 23 U USB Cable 3 Full Speed 1 Full...

Страница 47: ......

Страница 48: ...January 2006 Web 01 Only Printed in China 7 0 7 9 0 1 6 B...

Отзывы: