15
P
ROGRAMMING
M
ODES
The MS5145 Eclipse has 3 modes of programming.
Bar Codes
Eclipse can be configured by scanning the bar codes located in the
MetroSelect
®
Single-Line Configuration Guide (
MLPN
00-02544). Please
refer to this guide for instructions. This manual can be downloaded for
FREE from Metrologic’s website (www.metrologic.com).
MetroSet
®
2
This user-friendly Windows-based configuration program allows you to
simply ‘point-and-click’ at the desired scanner options. This program can be
downloaded for FREE from Metrologic’ website (www.metrologic.com), or
set-up disks can be ordered by calling 1-800-ID-METRO.
Serial Programming
This mode of programming is ideal for OEM applications. This mode gives
the end-user the ability to send a series of commands using the serial port of
the host system. The commands are equivalent to the numerical values of
the bar codes located in the MetroSelect Single-Line Configuration Guide
(
MLPN
00-02544).
How does Serial Programming work?
1. Each command sent to the scanner is the ASCII representation of each
numeral in the configuration bar code. The entire numeric string is framed
with an ASCII [stx] and an ASCII [etx].
EXAMPLE #1:
Command for Disabling Codabar
Command = [stx]100104[etx]
String Sent to Scanner = 02h 31h 30h 30h 31h 30h 34h 03h
(All values are hexadecimal).
2. If the command sent to the scanner is valid, the scanner will respond with an
[ack].
3. If the command sent to the scanner in invalid, the scanner will respond with
a [nak].
NOTE:
If this occurs, the end-user must start over at the very beginning of
the configuration sequence. Re-transmitting the invalid command
will not work, the user must start over.
Содержание Eclipse MS5145-00
Страница 1: ......
Страница 2: ......
Страница 23: ...19 SCAN AREA Minimum Bar Code Element Width A B C D E F mm 10 12 17 26 33 66 mils 4 1 4 8 6 8 10 4 13 26...
Страница 47: ......
Страница 48: ...January 2006 Web 01 Only Printed in China 7 0 7 9 0 1 6 B...