![Metrohm 863 Скачать руководство пользователя страница 37](http://html1.mh-extra.com/html/metrohm/863/863_manual_1779594037.webp)
■■■■■■■■■■■■■■■■■■■■■■
4 Automation sequences
863 Compact Autosampler
■■■■■■■■
29
4.6
VA 797 Manual start
This method template is suitable for sample transfer to a 797 VA Compu-
trace. The actual pump time is determined by the control software.
Preparing and starting the sample series
1
Press
[START]
.
2
Under
Number of samples
, enter the number of samples or the
maximum value of
99
.
3
Under
Next sample pos.
, enter the rack position of the first sample
to be processed.
4
Press
[START]
.
NOTICE
The method run will be automatically restarted for every sample via
remote connection (Autostart). A stepping pulse of the connected
instrument is expected at the beginning of the method run. The 863
Compact Autosampler may need to be stopped manually by means of
the button
[STOP]
after the processing of the last sample.
The individual steps of the method:
■
Wait for the stepping pulse
■
Move to the sample
■
Lower the lift to the work position
■
Wait for the stepping pulse
■
Switch on the peristaltic pump for the sample transfer
■
Wait for the minimum pump time to be completed
■
Wait for the stepping pulse
■
Switch off the peristaltic pump