19
SHK 200S
SHK 200S-6
5 Outdoor unit METROAIR L
Transport and storage
Assembly
Lift from the street to the set up
location
METROAIR L must be transported and stored vertically.
Do not place METROAIR L directly on the lawn or
other non solid surface.
If there is a risk of snow slip from roof, a protective
roof or cover must be erected to protect the heat
pump,pipes and wiring.
If the base allows, the simplest thing is to use a pallet
truck to move the METROAIR L to the set up location.
If METROAIR L needs to be transported across soft
ground,such as a lawn, we recommend that a crane
truck is used that can lift the unit to the installation lo-
cation. When METROAIR L is lifted with a crane, the
packaging must be undamaged and the load distrib-
uted with a boom,see the illustration above.
If a crane cannot be used METROAIR L can be trans
-
ported using an extended sack truck. METROAIR L
must be used on the side marked "heavy side" and
two people are required to get the METROAIR L up.
•
Place METROAIR L outdoors on a solid level
base that can take the weight, preferably a con-
crete foundation. If concrete slabs are used they
must rest on asphalt or shingle.
• The concrete foundation or slabs must be posi-
tioned so that the lower edge of the evaporator
is at the level of the average local snow depth;
however, a minimum of 300 mm. Stands and at-
tachments on the page are available in the MET
-
ROAIR L instruction in the "Accessories" chapter.
•
METROAIR L should not be positioned next to
noise sensitive walls, for example, next to a bed-
room.
• Also ensure that the placement does not incon-
venience the neighbours.
•
METROAIR L must not be placed so that recircu
-
lation of the outdoor air can occur. This causes
lower output and impaired efficiency.
• The evaporator should be sheltered from direct
wind, which negatively affects the defrosting
function. Place METROAIR L protected from
wind against the evaporator
• Large amounts of condensation water, as well
as melt water from defrosting, can be produced.
Condensation water must be led off to a drain or
similar (see page13).
• Care must be exercised so that the heat pump is
not scratched during installation.
IMPORTANT
Ensure that the heat pump cannot fall overduring trans-
port.
IMPORTANT
The centre of gravity is offset to one side (seep print on
the packaging).
LEK
XX mm
300 mm
Chapter 5 |
Outdoor unit METROAIR L
Содержание SHK 200S
Страница 2: ......
Страница 70: ...70 SHK 200S SHK 200S 6 Diagram of electrical connections Chapter 13 Technical data...
Страница 71: ...71 SHK 200S SHK 200S 6 Chapter 13 Technical data...
Страница 72: ...72 SHK 200S SHK 200S 6 Chapter 13 Technical data...
Страница 73: ...73 SHK 200S SHK 200S 6 Chapter 13 Technical data...
Страница 74: ...74 SHK 200S SHK 200S 6 Chapter 13 Technical data...
Страница 75: ...75 SHK 200S SHK 200S 6 Chapter 13 Technical data...
Страница 76: ...76 SHK 200S SHK 200S 6...
Страница 77: ...77 SHK 200S SHK 200S 6...
Страница 78: ...78 SHK 200S SHK 200S 6...
Страница 79: ......
Страница 80: ...METRO THERM A S RUNDINSVEJ 55 DK3200 HELSINGE INFO METROTHERM DK WWW METROTHERM DK 08 242 1909...