DESCRIPTION

THIS MANUAL COVERS CABINETS WITH ELECTRICAL RATINGS OF: 120V 60HZ 5.4A &  
220-240V 50HZ 2.7A

INSTRUCTIONS FOR USE 

 

R-SERIES MOBILE REFRIGERATORS

When ordering electrical parts, always  
confirm the rating listed on cabinet data plate on back of 
cabinet.

Differences in voltage, amps or wattage are listed with 

BOLD TEXT

 in replacement part descriptions.

Содержание R Series

Страница 1: ... 5 4A 220 240V 50HZ 2 7A INSTRUCTIONS FOR USE R SERIES MOBILE REFRIGERATORS When ordering electrical parts always confirm the rating listed on cabinet data plate on back of cabinet Differences in voltage amps or wattage are listed with BOLD TEXT in replacement part descriptions ...

Страница 2: ...ry or death from electrical malfunction Unplug the cabinet before cleaning and then wipe with a damp cloth and dry with a towel Use only mild soap or cleaning agents approved for stainless steel The accidental release of refrigerant gases can result in physical injuries Always wear eye protection and protect your hands face and body when servicing refrigeration system SAFETY SYMBOLS HAZARDOUS VOLT...

Страница 3: ... STEEL SLIDES L ADJUSTABLE LIP LOAD B ADJUSTABLE BOTTOM LOAD F FIXED LIP LOAD ACCESSORIES SERIES X 220 240V 50HZ BLANK 120V 60HZ Armour Panel Air Chimney Slides Door Gasket Analog Thermometer Door Latch Info Panel Refrigeration Cassette Door Slides and Upright Bumper 2 Brake Caster Front 2 Swivel Caster Rear R Refrigeration Front Panel Molded Corner Bumper Side Access Panel Power Cord Cord Holder ...

Страница 4: ...power cord is located at the back of the cabinet as shown in Figure 1 6 Refer to the data plate located near the power cord for the electrical specifications of cabinet as shown in Figure 2 With the POWER switch OFF plug the cord into the appropriate rated grounded receptacle Cabinets rated at 120V must be plugged into either a 15 amp or 20 amp 125 VAC receptacle Cabinets rated at 220 240V must be...

Страница 5: ...ier Installation of Fixed Slide Racks B A BOTTOM LOAD SLIDES AND UPRIGHTS 13 Levels Position from Bottom Bottom Load Part No RPC5R BL 13 Fixed Slide Bottom Mounting Bracket Top Mounting Bracket NOTE Door not shown for clarity 1 Piece Construction FULL HEIGHT Part No RPC5R FS 1 Pair LIP LOAD SLIDES AND UPRIGHTS 13 Levels Position from Bottom Lip Load Part No RPC5R LL 13 Fixed Slide Assembly for Com...

Страница 6: ...evate the cabinet air temperature above 40 F 4 C CARE AND MAINTENANCE Before proceeding with any maintenance activity strictly follow Safety Information on page 2 of this manual Regularly inspect the casters Tighten loose fasteners and replace worn or damaged parts with new InterMetro approved parts Replace worn or damaged casters immediately lubricate casters regularly if applicable Cleaning The ...

Страница 7: ...e intake cover Then verify no gaps are present along the top of the gasket B C A 1 Open cabinet door 2 Remove front panel Stop 3 Disconnect power switch wires 4 Remove ground wire from base 1 Remove stop from slide using screw driver 1 Unscrew jack bolts 4x using a 1 2 wrench to lower onto slide 2 Do not completely remove jack bolts 3 Loosen until they contact cabinet floor D 1 Pull cassette out C...

Страница 8: ...l of Brackets and Electronics from Refrigeration Cassette Unit Removal of Evaporator Fan Assembly from Refrigeration Cassette C B A REMOVE TEMPERATURE SENSOR D FEED WIRES UNDER GASKET Gasket P Clip REMOVE WIRES FROM P CLIPS REMOVE MOUNTING BOLTS TO DISASSEMBLE ELECTRONICS Bolts B A FAN ASSEMBLY ...

Страница 9: ...ly Look for any obvious defects on the capacitor and verify that the relay is operating Replace if needed Review controller operation Replace if necessary 5 Excessive noise from refrigeration unit Fan blade hitting shroud or loose fitting Re install fan blade correctly From the fan motor Replace the motor and fan From the inside of compressor Replace the refrigeration unit 6 Compressor starts but ...

Страница 10: ... 2 RPC13 940 CONTROLLER WITH SENSOR 220 240V 7 RPC5R9 DOOR COMPLETE DOOR ASSEMBLY 39 RPC13 834 FUSE 1 1 4 AMP 8 RPC14 330 DOOR HINGE 40 RPC13 557 FUSE HOLDER 9 RPC14 329 DOOR LATCH 41 RPC06 1097 1 SNAP BUSHING 10 RPC5R INFO COMPLETE INFO PANEL THERMOMETER ASSEMBLY 42 RPC13 375 RED MASTER SWITCH 11 RPC5R WHTBRD WHITE BOARD WITH CLIPS 43 RPC13 846 COMPRESSOR CABLE Shown on Page13 12 RPC13 829 THERMO...

Страница 11: ... REFRIGERATORS INSTRUCTIONS FOR USE 11 www metro com L01 499 REV G 02 20 8 4 5 7 10 2 3 9 11 12 14 15 16 18 17 19 20 23 24 27 26 29 28 1 Must be used with uprights 30 31 Typ 4 Places Cabinet Base Cassette Slide 13 49 ...

Страница 12: ...FOR USE 12 www metro com L01 499 REV G 02 20 21 22 34 REFRIGERATION CASSETTE ASSEMBLY 6 1 Inside 1 Outside 42 FRONT PANEL RIGHT ANGLE PLUG SHOWN 25 36 Defrost Temperature Sensor Supplied with Controller 44 45 32 37 35 33 40 41 38 39 48 46 47 51 ...

Страница 13: ...STER SWITCH GREEN GROUND SCREW GREEN YELLOW STRIP X 34 WIRE NUT POWER CORD STRAIN RELIEF GROUND STUD COMPRESSOR CABLE 28 BLACK X 10 GREEN BLACK FAN WIRING HARNESS 12 GA BLACK X 14 12 GA WHITE X 14 RED TO 4 WHITE TO 5 18 GA RED X 15 BLACK CUT TO 12 CUT TO 6 RED FUSE HOLDER 20 TERMINAL BLOCK 11 CUT TO 6 CUT TO 6 6 24 BLUE POWER SUPPLY BROWN 14 13 11 7 1 18 6 3 4 5 19 20 24 21 16 22 17 23 10 8 9 21 2...

Страница 14: ...S MOBILE REFRIGERATORS INSTRUCTIONS FOR USE 14 www metro com L01 499 REV G 02 20 02 2020 For online warranty registration please go to www metro com service support thermal cabinets to register electronically ...

Страница 15: ...R SERIES MOBILE REFRIGERATORS INSTRUCTIONS FOR USE 15 www metro com L01 499 REV G 02 20 THIS PAGE IS KEPT INTENTIONALLY BLANK ...

Страница 16: ... 2020 InterMetro Industries Corporation Wilkes Barre PA 18705 L01 499 REV G 02 20 ...

Отзывы: